Intrathoracic pressure regulation during cardiopulmonary resuscitation: a feasibility case-series.
MedLine Citation:
PMID:  22902465     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
AIM OF THE STUDY: Intrathoracic pressure regulation (IPR) is a novel, noninvasive therapy intended to increase cardiac output and blood pressure in hypotensive states by generating a negative end expiratory pressure of -12cm H2O between positive pressure ventilations. In this first feasibility case-series, we tested the hypothesis that IPR improves End tidal (ET) CO2 during cardiopulmonary resuscitation (CPR). ETCO2 was used as a surrogate measure for circulation. METHODS: All patients were treated initially with manual CPR and an impedance threshold device (ITD). When IPR-trained medics arrived on scene the ITD was removed and an IPR device (CirQLATOR™) was attached to the patient's advanced airway (intervention group). The IPR device lowered airway pressures to -9mmHg after each positive pressure ventilation for the duration of the expiratory phase. ETCO2, was measured using a capnometer incorporated into the defibrillator system (LifePak™). Values are expressed as mean±SEM. Results were compared using paired and unpaired Student's t test. P values of <0.05 were considered statistically significant. RESULTS: ETCO2 values in 11 patients in the case series were compared pre and during IPR therapy and also compared to 74 patients in the control group not treated with the new IPR device. ETCO2 values increased from an average of 21±1mmHg immediately before IPR application to an average value of 32±5mmHg and to a maximum value of 45±5mmHg during IPR treatment (p< 0.001). In the control group ETCO2 values did not change significantly. Return of spontaneous circulation (ROSC) rates were 46% (34/74) with standard CPR and ITD versus 73% (8/11) with standard CPR and the IPR device (p<0.001). CONCLUSIONS: ETCO2 levels and ROSC rates were significantly higher in the study intervention group. These findings demonstrate that during CPR circulation may be significantly augmented by generation of a negative end expiratory pressure between each breath.
Authors:
Nicolas Segal; Brent Parquette; Jonathon Ziehr; Demetris Yannopoulos; David Lindstrom
Related Documents :
22370685 - Development of an artificial placenta iv: 24 hour venovenous extracorporeal life suppor...
22433255 - The reliability of plantar pressure assessment during barefoot level walking in childre...
22715815 - Clinical review: update on neurally adjusted ventilatory assist - report of a round-tab...
22305295 - Impact of tissue volume and purification on clinical autologous islet transplantation f...
3958345 - Comparison of high pulse repetition frequency and continuous wave doppler echocardiogra...
17329135 - Blood pressure regulation in the three-toed sloth, bradypus variegatus.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-8-16
Journal Detail:
Title:  Resuscitation     Volume:  -     ISSN:  1873-1570     ISO Abbreviation:  Resuscitation     Publication Date:  2012 Aug 
Date Detail:
Created Date:  2012-8-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0332173     Medline TA:  Resuscitation     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012. Published by Elsevier Ireland Ltd.
Affiliation:
Department of Emergency Medicine, University of Minnesota, Minneapolis, MN, USA; Service des Urgences - Hôpital Lariboisière - Assistance Publique-Hôpitaux de Paris - Université Paris 7 Denis Diderot, Paris, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The Association Between Hospital Type and Mortality Among Critically Ill Children in US EDs.
Next Document:  Sensitivity of multi-parametric MRI to the compressive state of the isolated intervertebral discs.