Document Detail


Intrapartum uterine activity: evaluation of an intrauterine pressure transducer.
MedLine Citation:
PMID:  2915867     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A newly available intrauterine pressure transducer was evaluated clinically in 100 patients. Successful insertion was accomplished in 95%. There were no significant intrapartum maternal or fetal complications. Partial dehiscence of a surgically scarred uterus did occur in one patient who received the device, but a clear relationship between its attempted insertion and the dehiscence was not apparent. Early in the clinical trial, a number of devices malfunctioned; the manufacturer defined and remedied the problem. The intrauterine transducer required no maintenance and appeared to be practical in laboring women. We suggest that the utility of the intrauterine pressure transducer might be enhanced with several modifications, including the addition of a re-zeroing mechanism and a reduction in the device's length.
Authors:
T H Strong; R H Paul
Related Documents :
15792507 - Clinical experience with the intraparenchymal intracranial pressure monitoring codman m...
10146277 - The relationship between powder inhaler resistance and peak inspiratory conditions in h...
2930447 - An evaluation of the takeda ua751 automatic sphygmomanometer.
2040447 - Aerosol physiology, deposition, and metered dose inhalers.
1613567 - Simultaneous assessment of bolus transport and contraction parameters in multiple-swall...
17012527 - Effects of naltrexone on repressive coping and disclosure of emotional material: a test...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Obstetrics and gynecology     Volume:  73     ISSN:  0029-7844     ISO Abbreviation:  Obstet Gynecol     Publication Date:  1989 Mar 
Date Detail:
Created Date:  1989-03-23     Completed Date:  1989-03-23     Revised Date:  2009-10-26    
Medline Journal Info:
Nlm Unique ID:  0401101     Medline TA:  Obstet Gynecol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  432-4     Citation Subset:  AIM; IM    
Affiliation:
Department of Obstetrics and Gynecology, University of Southern California School of Medicine, Los Angeles.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Evaluation Studies as Topic
Female
Humans
Labor, Obstetric / physiology*
Monitoring, Physiologic / instrumentation*
Pregnancy
Transducers, Pressure
Uterus / physiology*
Comments/Corrections
Comment In:
Obstet Gynecol. 1989 Aug;74(2):283-4   [PMID:  2635882 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Brief sexual inquiry in gynecologic practice.
Next Document:  Use of the fibrin D-dimer in screening for coagulation abnormalities in preeclampsia.