Document Detail


Intraoperative electrophysiological monitoring in spine surgery.
MedLine Citation:
PMID:  21102290     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
STUDY DESIGN: Review of the literature with analysis of pooled data.
OBJECTIVE: To assess common intraoperative neuromonitoring (IOM) changes that occur during the course of spinal surgery, potential causes of change, and determine appropriate responses. Further, there will be discussion of appropriate application of IOM, and medical legal aspects. The structured literature review will answer the following questions: What are the various IOM methods currently available for spinal surgery? What are the sensitivities and specificities of each modality for neural element injury? How are the changes in each modality best interpreted? What is the appropriate response to indicated changes? Recommendations will be made as to the interpretation and appropriate response to IOM changes.
SUMMARY OF BACKGROUND DATA: Total number of abstracts identified and reviewed was 187. Full review was performed on 18 articles.
METHODS: The MEDLINE database was queried using the search terms IOM, spinal surgery, SSEP, wake-up test, MEP, spontaneous and triggered electromyography alone and in various combinations. Abstracts were identified and reviewed. Individual case reports were excluded. Detailed information and data from appropriate articles were assessed and compiled.
RESULTS: Ability to achieve IOM baseline data varied from 70% to 98% for somatosensory-evoked potentials (SSEP) and 66% to 100% for motor-evoked potentials (MEP) in absence of neural axis abnormality. Multimodality intraoperative neuromonitoring (MIOM) provided false negatives in 0% to 0.79% of cases, whereas isolated SSEP monitoring alone provided false negative in 0.063% to 2.7% of cases. MIOM provided false positive warning in 0.6% to 1.38% of cases.
CONCLUSION: As spine surgery, and patient comorbidity, becomes increasingly complex, IOM permits more aggressive deformity correction and tumor resection. Combination of SSEP and MEP monitoring provides assessment of entire spinal cord functionality in real time. Spontaneous and triggered electromyography add assessment of nerve roots. The wake-up test can continue to serve as a supplement when needed. MIOM may prove useful in preservation of neurologic function where an alteration of approach is possible. IOM is a valuable tool for optimization of outcome in complex spinal surgery.
Authors:
Neil R Malhotra; Christopher I Shaffrey
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Spine     Volume:  35     ISSN:  1528-1159     ISO Abbreviation:  Spine     Publication Date:  2010 Dec 
Date Detail:
Created Date:  2010-11-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7610646     Medline TA:  Spine (Phila Pa 1976)     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2167-79     Citation Subset:  IM    
Affiliation:
Department of Neurological Surgery, University of Pennsylvania School of Medicine, Pennsylvania Hospital, Philadelphia, PA 19107, USA. neil.malhotra@uphs.upenn.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Penetrating spinal injury with a wooden fragment: a case report and review of the literature.
Next Document:  Establishing a standard of care for neuromonitoring during spinal deformity surgery.