Document Detail


Intracoronary heparin delivery in humans. Acute feasibility and long-term results.
MedLine Citation:
PMID:  7586346     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Inefficacy of systemic drug administration for restenosis prevention may partially relate to insufficient local drug concentration. This study aimed to evaluate the acute feasibility and long-term outcome of using an infusion-perfusion coil balloon, Dispatch. METHODS AND RESULTS: In 22 patients after balloon angioplasty, the coil balloon was studied for (1) feasibility of local heparin delivery, (2) symptoms and signs of ischemia during prolonged deployment compared with angioplasty balloon occlusion, (3) coronary pressure and flow distal to the inflated device, and (4) long-term clinical and angiographic results. During prolonged intracoronary deployment of the coil balloon (29 +/- 8 minutes), 5 of 22 patients developed mild chest pain versus 20 of 22 during angioplasty (275 +/- 283 seconds). Neither hemodynamic nor vectorcardiographic signs of ischemia were detected, in contrast to angioplasty balloon occlusion. Baseline flow across the coil balloon was 44 +/- 31 mL/min, increasing by a factor of 1.8 +/- 0.7 during pharmacologically induced hyperemia. A mean volume of 14.2 +/- 6.1 mL containing 1416 +/- 608 IU of heparin was infused locally at a pressure of 122 +/- 54 mm Hg. At 7 +/- 1-month follow-up, 1 asymptomatic patient had died, and of the remaining 21, 17 (81%) were asymptomatic. Angiographic follow-up was obtained in 15 of 21 patients (71%), including all 4 symptomatic patients. Mean minimal luminal diameter after the procedure was 2.16 +/- 0.49 mm and at follow-up, 1.89 +/- 0.45 mm, which corresponds to a restenosis rate (diameter stenosis > or = 50%) of 7% (1/15). CONCLUSIONS: Intracoronary use of the coil balloon after balloon angioplasty proved to be feasible and subjectively as well as objectively well tolerated during prolonged deployment by virtue of its perfusion properties. High volumes of heparin solution can be infused locally at very low pressure. No unfavorable clinical or angiographic long-term effects were observed.
Authors:
E Camenzind; P P Kint; C Di Mario; J Ligthart; W van der Giessen; E Boersma; P W Serruys
Related Documents :
11771866 - Renovascular hypertension in children.
3157736 - Left ventricular wall stress and function in childhood coarctation of the aorta.
23355126 - Reduction of cardiovascular risk through angiotensin ii type 1 receptor antagonism : fo...
23753406 - Activation of neuronal transient receptor potential vanilloid 1 channel underlies 20-hy...
8018086 - An acute animal model that simulates the hemodynamic situations present during +gz acce...
1920186 - Baroreflex sensitivity at rest and during stress in individuals with a history of vasov...
Publication Detail:
Type:  Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Circulation     Volume:  92     ISSN:  0009-7322     ISO Abbreviation:  Circulation     Publication Date:  1995 Nov 
Date Detail:
Created Date:  1995-12-20     Completed Date:  1995-12-20     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0147763     Medline TA:  Circulation     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  2463-72     Citation Subset:  AIM; IM    
Affiliation:
Cardiac Catheterization Laboratory, University Hospital Dijkzigt, Rotterdam, Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Angioplasty, Transluminal, Percutaneous Coronary / adverse effects*
Anticoagulants / administration & dosage*
Cohort Studies
Coronary Circulation
Drug Delivery Systems / instrumentation*
Female
Heparin / administration & dosage*
Humans
Male
Middle Aged
Myocardial Ischemia / physiopathology,  prevention & control*
Chemical
Reg. No./Substance:
0/Anticoagulants; 9005-49-6/Heparin

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Coronary arterial flow-velocity dynamics in children with angiographically normal coronary arteries.
Next Document:  Relation of coronary angioscopic findings at coronary angioplasty to angiographic restenosis.