Document Detail


Intra- and interobserver reliability of umbilical vein blood flow.
MedLine Citation:
PMID:  18925616     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: To assess the intra- and interobserver reliability of the umbilical vein (UV) diameter, time-averaged maximum velocity (TAMX) and umbilical vein blood flow (BF). METHODS: Sixty-three consecutive singleton pregnancies between 24 and 42 weeks were evaluated by two independent operators. UV diameter and TAMX were measured. UV flow was calculated as UV area x 60 x TAMX x 0.5. Reliability analyses were performed by means of the intraclass correlation coefficient (ICC) for agreement. Differences between and within observers were explored and agreement limits calculated by means of the Bland-Altman test. RESULTS: Satisfactory Doppler parameters were successfully obtained from all fetuses. The intraobserver ICCs for UV diameter, TAMX, and BF were 0.7, 0.59, and 0.55, respectively, whereas the interobserver ICCs were 0.65, 0.46, and 0.60, respectively. The 95% confidence intervals of the intraobserver differences were (+0.15, -0.14), (+8.0, -7.9), and (+150, -138.7), respectively. The 95% confidence intervals of the interobserver differences were (+0.16, -0.16), (+8.5, -8.2), and (+138.8, -141.9), respectively. CONCLUSIONS: Noninvasive Doppler calculation of umbilical vein blood flow and its components are reliable enough for clinical use.
Authors:
Susana Fernandez; Francesc Figueras; Olga Gomez; Josep Maria Martinez; Elisenda Eixarch; Montserrat Comas; Bienvenido Puerto; Eduard Gratacos
Related Documents :
2300346 - Effect of epidural anesthesia for cesarean delivery on maternal femoral arterial and ve...
7435536 - Umbilical venous blood flow and its distribution before and during autonomic blockade i...
8231326 - Haemodynamic changes in iugr fetus with chronic hypoxia evaluated by fetal heart-rate m...
1315096 - Doppler blood flow changes and placental morphology in pregnancies with third trimester...
2523416 - Evaluation of gingival microcirculation by a laser-doppler flowmeter. preliminary results.
162186 - A doppler ultrasound technique for measuring human milk flow.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Prenatal diagnosis     Volume:  28     ISSN:  0197-3851     ISO Abbreviation:  Prenat. Diagn.     Publication Date:  2008 Nov 
Date Detail:
Created Date:  2008-11-05     Completed Date:  2009-03-19     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8106540     Medline TA:  Prenat Diagn     Country:  England    
Other Details:
Languages:  eng     Pagination:  999-1003     Citation Subset:  IM    
Affiliation:
Fetal Medicine Department, Hospital Clinic, Universitat de Barcelona, IDIBAPS, Barcelona, Spain. sufernan@clinic.ub.es
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Flow Velocity*
Female
Fetal Development
Gestational Age
Humans
Observer Variation*
Pregnancy
Pregnancy Trimester, Second
Umbilical Veins / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Characterization of Bet v 1-related allergens from kiwifruit relevant for patients with combined kiw...
Next Document:  Hypophosphatasia: molecular testing of 19 prenatal cases and discussion about genetic counseling.