Interventional 4-D C-arm CT Perfusion Imaging Using Interleaved Scanning and Partial Reconstruction Interpolation.
MedLine Citation:
PMID:  22203707     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Tissue perfusion measurement during catheterguided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel approach that uses a C-arm angiography system capable of CT-like imaging (C-arm CT) for this purpose. With C-arm CT one reconstructed volume can be obtained every 46 s which makes it challenging to measure the flow of an injected contrast bolus. We have developed an interleaved scanning (IS) protocol that uses several scan sequences to increase temporal sampling. Using a dedicated 4-D reconstruction approach based on partial reconstruction interpolation (PRI) we can optimally process our data. We evaluated our combined approach (IS-PRI) with simulations and a study in 5 healthy pigs. In our simulations, the cerebral blood flow values (unit: ml/100g/min) were 60 (healthy tissue) and 20 (pathological tissue). For one scan sequence the values were estimated with standard deviations of 14.3 and 2.9, respectively. For two interleaved sequences the standard deviations decreased to 3.6 and 1.5, respectively. We used perfusion CT to validate the in vivo results. With two interleaved sequences we achieved promising correlations ranging from r=0.63 to r=0.94. The results suggest that C-arm CT tissue perfusion imaging is feasible with two interleaved scan sequences.
Authors:
A Fieselmann; A Ganguly; Y Deuerling-Zheng; M Zellerhoff; C Rohkohl; J Boese; J Hornegger; R Fahrig
Related Documents :
7648587 - Venography with carbon dioxide as a contrast agent.
15280977 - Use of the curved linear-array echo endoscope to identify gastrorenal shunts in patient...
21215317 - Detection of mechanical injury of articular cartilage using contrast enhanced computed ...
11153197 - Superior sagittal sinus and cerebral cortical venous thrombosis caused by congenital pr...
8741327 - Masked ureteral duplication with ectopic ureter detected by magnetic resonance imaging.
7063697 - Radiation exposure reduction using carbon fiber.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-23
Journal Detail:
Title:  IEEE transactions on medical imaging     Volume:  -     ISSN:  1558-0062     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8310780     Medline TA:  IEEE Trans Med Imaging     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Constrained Registration for Motion Compensation in Atrial Fibrillation Ablation Procedures.
Next Document:  Interactive Image Segmentation Using Dirichlet Process Multiple View Learning.