Document Detail


Internal atrial defibrillation: effect on sinus and atrioventricular nodal function and implanted cardiac pacemakers.
MedLine Citation:
PMID:  9358485     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Internal atrial defibrillation (IAD) has been extensively evaluated for clinical efficacy but the need for concomitant demand pacing and the effect of IAD shocks on pacemaker function is not well studied. We prospectively evaluated: (1) the incidence of bradycardia as a result of IAD shocks; and (2) effect of these shocks on functioning of implanted cardiac pacemakers. Consecutive consenting patients with atrial fibrillation (AF) requiring cardioversion or undergoing electrophysiological study were selected for IAD. IAD shocks were delivered using the right ventricle to right atrium (RV-RA), right ventricle to superior vena cava (RV-SVC), right atrium to axillary patch (RA-AX), and right atrium to left pulmonary artery or coronary sinus (RA-LPA/CS) lead configurations. Mean RR interval before and after the shocks and the time interval from shock delivery to first QRS complex were analyzed for unsuccessful and successful shocks. Pacing and sensing function was analyzed in patients with previously implanted pacemakers. Twenty-five patients, 18 men, mean age 67.9 +/- 10 years were included in the study. A total of 305 shocks (264 unsuccessful, 41 successful) were analyzed. For unsuccessful shocks the mean post-IAD shock RR interval (795 +/- 205 ms) and the time to first post-IAD shock QRS complex (970 +/- 438 ms) were both significantly greater than the pre-IAD shock RR interval (685 +/- 131 ms, P < 0.001). The increase in post-IAD shock RR interval and time to first post-IAD shock QRS complex was seen with all four lead configurations used. With successful shocks the mean post-IAD shock sinus cycle length (1,105 +/- 450 ms) and time to first post-IAD shock QRS complex (1,126 +/- 443 ms) were both also significantly greater than the pre-IAD shock RR interval (766 +/- 172 ms). Nine patients (36%) had episodes of significant bradycardia after shock delivery. Shocks of up to 20 J using the RA-LPA/CS lead configuration did not affect pacemaker function. IAD can result in transient bradycardia related to sinus and atrioventricular nodal effects requiring backup ventricular pacing. Shocks can be safely delivered using RA-LPA or RA-CS lead configurations in patients with implanted bipolar cardiac pacemakers.
Authors:
A Prakash; S Saksena; P Mathew; R B Krol
Related Documents :
6673295 - Sequential external counterpulsation (secp) in china.
3109805 - Use of nitroglycerin in the treatment of acute heart failure and cardiogenic shock in p...
11508795 - Intranuclear ubiquitin immunoreactivity in the pigmented neurons of the substantia nigr...
16810575 - Inferior wall myocardial infarction with or without right ventricular involvement--trea...
2559805 - Density of beta adrenoceptors in rat heart and lymphocytes 48 hours and 7 days after ac...
12727575 - Third heart sound and elevated jugular venous pressure as markers of the subsequent dev...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  20     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  1997 Oct 
Date Detail:
Created Date:  1997-12-19     Completed Date:  1997-12-19     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  2434-41     Citation Subset:  IM    
Affiliation:
Arrhythmia and Pacemaker Service, Eastern Heart Institute, Passaic, New Jersey, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Atrial Fibrillation / physiopathology,  therapy*
Atrial Flutter / physiopathology,  therapy*
Atrioventricular Node / physiopathology*
Bradycardia / etiology
Electric Countershock* / adverse effects,  methods
Female
Humans
Male
Pacemaker, Artificial*
Sinoatrial Node / physiopathology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Atrial pacing leads following open heart surgery: active or passive fixation?
Next Document:  A comparison of transvenous atrial defibrillation of acute and chronic atrial fibrillation and the e...