Insights from three-dimensional echocardiographic laser stereolithography. Effect of leaflet funnel geometry on the coefficient of orifice contraction, pressure loss, and the Gorlin formula in mitral stenosis.
MedLine Citation:
PMID:  8759088     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Three-dimensional echocardiography can allow us to address uniquely three-dimensional scientific questions, for example, the hypothesis that the impact of a stenotic valve depends not only on its limiting orifice area but also on its three-dimensional geometry proximal to the orifice. This can affect the coefficient of orifice contraction (Cc = effective/anatomic area), which is important because for a given flow rate and anatomic area, a lower Cc gives a higher velocity and pressure gradient, and Cc, routinely assumed constant in the Gorlin equation, may vary with valve shape (60% for a flat plate, 100% for a tube). To date, it has not been possible to study this with actual valve shapes in patients. METHODS AND RESULTS: Three-dimensional echocardiography reconstructed valve geometries typical of the spectrum in patients with mitral stenosis: mobile doming, intermediate conical, and relatively flat immobile valves. Each geometry was constructed with orifice areas of 0.5, 1.0 and 1.5 cm2 by stereolithography (computerized laser polymerization) (total, nine valves) and studied at physiological flow rates. Cc varied prominently with shape and was larger for the longer, tapered dome (more gradual flow convergence proximal and distal to the limiting orifice): for an anatomic orifice of 1.5 cm2, Cc increased from 0.73 (flat) to 0.87 (dome), and for an area of 0.5 cm2, from 0.62 to 0.75. For each shape, Cc increased with increasing orifice size relative to the proximal funnel (more tubelike). These variations translated into important differences of up to 40% in pressure gradient for the same anatomic area and flow rate (greatest for the flattest valves), with a corresponding variation in calculated Gorlin area (an effective area) relative to anatomic values. CONCLUSIONS: The coefficient of contraction and the related net pressure loss are importantly affected by the variations in leaflet geometry seen in patients with mitral stenosis. Three-dimensional echocardiography and stereolithography, with the use of actual information from patients, can address such uniquely three-dimensional questions to provide insight into the relations between cardiac structure, pressure, and flows.
Authors:
D Gilon; E G Cape; M D Handschumacher; L Jiang; C Sears; J Solheim; E Morris; J T Strobel; S M Miller-Jones; A E Weyman; R A Levine
Related Documents :
18207358 - Reliable time to estimate subglottal pressure.
15908258 - Determination of the pressure required to cause mitral valve failure.
6478568 - Noninvasive estimation of right ventricular systolic pressure by doppler ultrasound in ...
24275838 - Destiffening effect of valsartan and atenolol: influence of heart rate and blood pressure.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Circulation     Volume:  94     ISSN:  0009-7322     ISO Abbreviation:  Circulation     Publication Date:  1996 Aug 
Date Detail:
Created Date:  1996-12-11     Completed Date:  1996-12-11     Revised Date:  2007-11-14    
Medline Journal Info:
Nlm Unique ID:  0147763     Medline TA:  Circulation     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  452-9     Citation Subset:  AIM; IM    
Affiliation:
Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston 02114, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Pressure*
Echocardiography*
Humans
Image Processing, Computer-Assisted*
Lasers / diagnostic use*
Mitral Valve Stenosis / pathology*,  physiopathology*
Models, Cardiovascular*
Myocardial Contraction*
Grant Support
ID/Acronym/Agency:
R01-HL-53702/HL/NHLBI NIH HHS