Document Detail


Input impedance of radiocephalic arteriovenous fistulae for haemodialysis access: its value in predicting early failure.
MedLine Citation:
PMID:  7881368     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This study is concerned with an assessment of the quality of the blood vessels used in the construction of radiocephalic arteriovenous fistulae for haemodialysis vascular access in 20 patients. Following non-invasive preoperative assessment of the cephalic vein by means of a colour Doppler scanner, input impedance was determined intraoperatively from blood flow and blood pressure measured about 2 cm downstream of the anastomosis. The patients were re-assessed 1 day and 2, 4, 6 and 12 weeks after surgery, and the diameter and the flow through the fistulae, the location of major branches, and the presence and severity of stenoses in the cephalic veins were determined non-invasively. Five fistulae failed within the 12 weeks period following surgery, mainly due to thrombosis. In a further 3 patients, the fistulae were patent but did not achieve an adequately high blood flow and dilate sufficiently for haemodialysis and were therefore considered to be essentially failed. The impedance moduli from 0 to 10 Hz as well as the average impedance modulus of successful fistulae were significantly lower than those of fistulae that subsequently failed. An attempt was made to locate the presence of reflection sites (i.e. stenoses and branches) from the minima in the impedance modulus spectra. Their locations were compared with those of the reflection sites detected by ultrasound 2 weeks after surgery. However, not all reflection sites detected 2 weeks after surgery were located by the impedance method. It is recommended that both preoperative examination and intraoperative haemodynamic measurements be made to improve the accuracy of the assessment.
Authors:
V Wong; T V How; R Ward; J Taylor; S Selvakumar; A Bakran
Related Documents :
3189568 - Total and regional blood flows in vascularized skeletal muscle grafts in rabbits.
9814798 - Failed coronary artery bypass anastomosis detected by intraoperative coronary flow meas...
2144088 - Electro-thermometric study on the healing of free gingival grafts covered by two differ...
22332958 - Acute hyperfibrinogenemia impairs cochlear blood flow and hearing function in guinea pi...
9293408 - Flow-mediated vasodilation of a conduit artery in relation to downstream peripheral tis...
7420168 - Effect of experimental subarachnoid hemorrhage on the adrenergic innervation of cerebra...
Publication Detail:
Type:  Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Physiological measurement     Volume:  15     ISSN:  0967-3334     ISO Abbreviation:  Physiol Meas     Publication Date:  1994 Nov 
Date Detail:
Created Date:  1995-04-10     Completed Date:  1995-04-10     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  469-80     Citation Subset:  IM    
Affiliation:
Department of Clinical Engineering, University of Liverpool, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Arteriovenous Shunt, Surgical*
Blood Pressure / physiology
Cerebral Veins / surgery*,  ultrasonography
Humans
Intraoperative Period
Preoperative Care
Prognosis
Radial Artery / surgery*,  ultrasonography
Regional Blood Flow / physiology
Renal Dialysis / methods*
Spasm / physiopathology

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A comparison of electrodes for potential use in paediatric/infant apnoea monitoring.
Next Document:  Physiological characteristics of inferior vena cava pulse waveform during foetal development.