Influence of different cuff inflation protocols on capillary filtration capacity in human calves -- a congestion plethysmography study.
MedLine Citation:
PMID:  12231656     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
It has been suggested that venous congestion plethysmography (VCP) substantially underestimates microvascular permeability by activation of a veni-arteriolar constrictor mechanism, even when using small (< 25 mmHg) congestion pressure steps. We studied human lower limbs of 18 young healthy volunteers to test whether the congestion pressure step size of the VCP protocol has an influence on the values of the capillary filtration capacity (CFC) and isovolumetric venous pressure (P(vi)). Two different dual stage VCP pressure step protocols, with 3 and 10 mmHg steps, were used in randomised order and separated by a transient reduction in congestion pressure. Since lymph flow is known to increase after venous congestion, we also looked to see if changes in the estimated lymph flow (J(v)L) occur as a result of these VCP protocols. The measured CFC (median [25th; 75th percentile]) was 2.6 [2.5; 3.2] x 10(-3) ml (100 ml)(-1) min(-1) mmHg(-1) with the 3 mmHg pressure step protocol, which was not different from the value of 2.9 [2.7; 3.4] x 10(-3) ml (100 ml)(-1) min(-1) mmHg(-1) obtained with 10 mmHg pressure steps. However, when either of these step sizes was applied after a transient venous decongestion, significantly higher values of CFC, 4.0 [3.4; 4.1] x 10(-3) and 3.5 [3.1; 4.5] x 10(-3) ml (100 ml)(-1) min(-1) mmHg(-1), respectively, were obtained (P < 0.05). The assessment of P(vi) was also independent of the pressure protocol (10 mmHg: 8.0 [5.7; 13.2] mmHg and 3 mmHg: 15.7 [12.5; 18.5] mmHg), but when P(vi) was measured after the transient deflation, significantly higher values were found with both 10 and 3 mmHg steps (24.1 [20.9; 27.3] and 30.4 [28.9; 30.9] mmHg, respectively; P < 0.01). The transient pressure reduction was associated with a rise in estimated J(v)L from 0.04 [0.03; 0.05] to 0.12 [0.08; 0.18] and 0.04 [0.04; 0.05] to 0.09 [0.07; 0.10] ml (100 ml)(-1) min(-1), respectively (P < 0.01). The first stage data from these protocols shows that the value of CFC is not influenced by the size of the cumulative venous pressure steps, providing they are of 10 mmHg or less. The data also show that J(v)L can be estimated with small step VCP protocols. We hypothesise that the sudden reduction in cuff pressure after venous congestion is associated with a temporary upregulation of lymph flow. As the congestion pressure is raised again, there is a modulation of the enhanced lymph flow, such that the resulting CFC slope appears greater than that obtained in the first stage of the protocol.
Authors:
A Bauer; D Bruegger; J Gamble; F Christ
Related Documents :
12865836 - Pressurization of vertebral bodies during vertebroplasty causes cardiovascular complica...
110756 - Isoproterenol and aminophylline reduce lung capillary filtration during high permeability.
7006136 - The effect of prostacyclin infusion on endotoxin-induced lung injury.
10194196 - Role of l-selectin in physiological manifestations after burn and smoke inhalation inju...
24627356 - Time courses of central hemodynamics during rapid changes in posture.
12487396 - The heart-pump interaction: effects of a microaxial blood pump.
Publication Detail:
Type:  Clinical Trial; Controlled Clinical Trial; Journal Article    
Journal Detail:
Title:  The Journal of physiology     Volume:  543     ISSN:  0022-3751     ISO Abbreviation:  J. Physiol. (Lond.)     Publication Date:  2002 Sep 
Date Detail:
Created Date:  2002-09-16     Completed Date:  2003-02-25     Revised Date:  2013-06-09    
Medline Journal Info:
Nlm Unique ID:  0266262     Medline TA:  J Physiol     Country:  England    
Other Details:
Languages:  eng     Pagination:  1025-31     Citation Subset:  IM    
Affiliation:
Clinic for Anaesthesiology, Ludwig-Maximilians University Munich, 81377 Munich, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Blood Pressure Determination / instrumentation
Capillaries / physiology*
Capillary Permeability / physiology
Female
Humans
Leg / blood supply*
Male
Plethysmography / instrumentation,  methods*
Tourniquets
Venous Pressure / physiology
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The role of adenosine in regulation of cerebral blood flow during hypoxia in the near-term fetal she...
Next Document:  Regional fat metabolism in human splanchnic and adipose tissues; the effect of exercise.