Influence of central corneal thickness on measured intraocular pressure differentials: Nidek RKT-7700, Topcon CT-80 NCTs and Goldmann Tonometer.
MedLine Citation:
PMID:  23009324     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE: We sought to compare the intraocular pressure (IOP) measured by RKT-7700 and CT-80 noncontact tonometers (NCTs) with that measured by Goldmann applanation tonometry (GAT). We also examined the influence of central corneal thickness (CCT) on the agreement between both NCTs and GAT in a sub-population of healthy, young normals. METHODS: Triplicate IOP and CCT measurements were obtained twice from one randomized eye of 49 subjects (28 males and 21 females) aged 22.2 ± 1.3 (mean ± S.D.) years. Goldmann tonometry was performed subsequent to assessment with the RKT-7700 and CT-80, to negate the 'ocular massage effect', followed by ultrasound pachymetry. The results from each method were compared and assessed for repeatability and between-observer reproducibility. Analysis was performed to determine the correlation between the differences in IOP measurements and corneal thicknesses. RESULTS: The mean differences (±S.D.) in sessions 1 and 2 respectively between RKT-7700 and GAT (2.6 ± 2.0 and 2.7 ± 1.4 mmHg), between CT-80 and GAT (2.8 ± 2.0 and 3.2 ± 1.3 mmHg) were statistically significant (p < 0.0001). The repeatability coefficients in sessions 1 and 2 respectively were; ±1.2 and ±1.0 mmHg (GAT), ±1.3  and ±1.6 mmHg (CT-80), ±2.3  and ±1.7 mmHg (RKT-7700) and inter-observer reproducibility was; ±1.9 (RKT-7700), ±2.3 (GAT) and ±2.6 mmHg (CT-80). Between the corneal thickness and the differences in GAT-measured and NCT-measured IOPs, there was a significant negative correlation and a trend for a larger difference in thicker corneas. CONCLUSION: Neither the RKT-7700 nor the CT-80 can be used interchangeably with the Goldmann tonometer, although all three tonometers give repeatable measurements of IOP, in this sub-population. IOP differences between GAT and the NCTs significantly correlated with CCT, with the possibility of even greater differences in thicker corneas.
Authors:
Kelechi C Ogbuehi; Sven Mucke; Uchechukwu L Osuagwu
Related Documents :
6547124 - Respiratory effects of progressive asphyxia in rabbit pups and adult rabbits.
6461284 - Effects of inspiratory loading on respiratory muscle activity during expiration.
22699734 - The incidence of pressure ulcers after the implementation of a prevention protocol.
23211824 - The effect of size and species on lens intracellular hydrostatic pressure.
9241324 - The combination of external high-frequency oscillation and pressure support ventilation...
9464584 - Cardioprotective efficacy of ischemic preconditioning on long-term myocardial ischemia.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-9-26
Journal Detail:
Title:  Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)     Volume:  -     ISSN:  1475-1313     ISO Abbreviation:  Ophthalmic Physiol Opt     Publication Date:  2012 Sep 
Date Detail:
Created Date:  2012-9-26     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8208839     Medline TA:  Ophthalmic Physiol Opt     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Ophthalmic & Physiological Optics © 2012 The College of Optometrists.
Affiliation:
Corneal Research Chair, Department of Optometry and Vision Sciences, King Saud University, Riyadh, Saudi Arabia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Hyperbaric oxygen therapy alleviates oxidative stress and tissue injury in renal ischemia/reperfusio...
Next Document:  The relationship between obesity and prostate cancer: from genetics to disease treatment and prevent...