| Influence of Hemodynamic Factors on Rupture of Intracranial Aneurysms: Patient-Specific 3D Mirror Aneurysms Model Computational Fluid Dynamics Simulation. | |
| | |
MedLine Citation:
|
PMID: 21757526 Owner: NLM Status: Publisher |
Abstract/OtherAbstract:
|
BACKGROUND AND PURPOSE: Hemodynamics factors play an important role in the rupture of cerebral aneurysms. The purpose of this study was to evaluate the impact of hemodynamic factors on the rupture of the MANs with 3D reconstruction model CFD simulation. MATERIALS AND METHODS: RDSA was performed in 9 pairs of intracranial MANs. Each pair was divided into ruptured and unruptured groups. The hemodynamic factors of the aneurysms and their parent arteries were compared. RESULTS: There was a significant difference in the WSS at peak systole between the regions of the aneurysms and their parent arteries in the ruptured group (ie, 6.49 ± 3.48 Pa versus 8.78 ± 3.57 Pa, P = .015) but not in the unruptured group (ie, 9.80 ± 4.12 Pa versus 10.17 ± 7.48 Pa, P = .678). The proportion of the low WSS area to the whole area of the aneurysms was 12.20 ± 18.08% in the ruptured group and 3.96 ± 6.91% in the unruptured group; the difference between the 2 groups was statistically significant (P = .015). The OSI was 0.0879 ± 0.0764 in the ruptured group, which was significantly higher than that of the unruptured group (ie, 0.0183 ± 0.0191, P = .008). CONCLUSIONS: MANs may be a useful disease model to investigate possible causes linked to ruptured aneurysms. The ruptured aneurysms manifested lower WSS compared with their parent arteries, a higher proportion of the low WSS area to the whole area of aneurysm, and higher OSI compared with the unruptured aneurysms. |
| | |
Authors:
|
G Lu; L Huang; X L Zhang; S Z Wang; Y Hong; Z Hu; D Y Geng |
Related Documents
:
|
20059766 - A prospective evaluation of the safety and efficacy of the taxus element paclitaxel-elu... 19729536 - Treatment of stenoses of vertebral artery origin using short drug-eluting coronary sten... 19901426 - Complex intervention of an in-stent restenosis of ostial right coronary artery stent pr... 21069326 - Carotid stenting for restenosis after endarterectomy. 8377236 - Paraanastomotic aneurysms of the abdominal aorta. 18705436 - Double orifice mitral valve: a report of two cases. |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2011-7-14 |
Journal Detail:
|
Title: AJNR. American journal of neuroradiology Volume: - ISSN: 1936-959X ISO Abbreviation: - Publication Date: 2011 Jul |
Date Detail:
|
Created Date: 2011-7-15 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 8003708 Medline TA: AJNR Am J Neuroradiol Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Affiliation:
|
Shanghai Department of Radiology and Department of Mechanics and Engineering Science, Fudan University, Huashan Hospital, Shanghai, China. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Assessment of the Virchow-Robin Spaces in Alzheimer Disease, Mild Cognitive Impairment, and Normal A...
Next Document: Evaluation of a Second-Generation Self-Expanding Variable-Porosity Flow Diverter in a Rabbit Elastas...