| Influence of 8 and 24-h storage of whole blood at ambient temperature on prothrombin time, activated partial thromboplastin time, fibrinogen, thrombin time, antithrombin and D-dimer. | |
| | |
MedLine Citation:
|
PMID: 21297453 Owner: NLM Status: Publisher |
Abstract/OtherAbstract:
|
This study evaluates the effect of whole blood storage on common coagulation parameters in order to confirm or revise acceptable storage limits as defined by current guidelines and diverse study reports. Aliquots were taken from the citrated whole blood of inpatients and outpatients (n = 147) within 4 h after blood withdrawal and after extended storage of whole blood for 8 and 24 h at ambient temperature. Aliquots were centrifuged and analyzed for prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (Fbg), antithrombin (AT), thrombin time (TT) and D-dimer. For each parameter, samples from 33-56 patients were investigated covering a wide range of normal and pathological values. Samples from patients receiving heparin were excluded from analyses of APTT and TT. All assays were performed using reagents and an analyzer from Siemens Healthcare Diagnostics Products GmbH. The mean percentage change after 8 and 24-h storage was below 10% for all parameters. Considering the changes in individual samples, all parameters can be reliably tested after 8-h storage, since less than 15% of the samples demonstrated individual changes of above 10%. The acceptable storage time can be extended to 24 h for PT, TT and D-dimer. Clinically relevant changes were detected after 24-h storage for APTT: 41% of the investigated samples demonstrated changes of above 10%. After 24-h storage, changes for Fbg and AT values were more than 15% in five out of 49 and in three out of 45 samples, respectively. This sporadic increase of values is clinically acceptable except for borderline samples. |
| | |
Authors:
|
Bettina Kemkes-Matthes; Ronald Fischer; Dirk Peetz |
Related Documents
:
|
11807723 - Blood group and susceptibility to disease caused by escherichia coli o157. 20859513 - The evaluation of iron deficiency and anemia in male blood donors with other related fa... 22044443 - Demographic differences in estimated blood donor eligibility prevalence in the united s... |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2011-2-3 |
Journal Detail:
|
Title: Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis Volume: - ISSN: 1473-5733 ISO Abbreviation: - Publication Date: 2011 Feb |
Date Detail:
|
Created Date: 2011-2-7 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 9102551 Medline TA: Blood Coagul Fibrinolysis Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Affiliation:
|
aHemostasis Center, University Hospitals Giessen and Marburg GmbH, Giessen, Germany bDepartments of Clinical Chemistry and Laboratory Medicine, University Center of the Johannes Gutenberg University Mainz, Mainz, Germany cInstitute of Laboratory Medicine, HELIOS Klinikum Berlin-Buch, Berlin, Germany. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Hemorrhagic manifestation of megaloblastic anemia: report of two cases and literature review.