Document Detail


Inferior orbital septum release compared with lateral canthotomy and cantholysis in the management of orbital compartment syndrome.
MedLine Citation:
PMID:  22262289     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
PURPOSE: : The purpose of this study is to assess the utility of inferior orbital septum release compared with lateral canthotomy and inferior cantholysis for the treatment of orbital compartment syndrome.
METHOD: : An experimental study design using a cadaver model for orbital compartment syndrome was used to compare the efficacy of inferior orbital septum release with lateral canthotomy and inferior cantholysis. Elevated orbital compartment pressures were created in a total of 10 orbits of 5 fresh cadaver heads. Compartment pressure and intraocular pressure were measured before and after inferior orbital septum release and lateral canthotomy/cantholysis. Additionally, orbital compartment pressure was compared with intraocular pressure at various pressures to assess correlation. Statistical analysis was performed on the collected data for efficacy comparison of the 2 procedures.
RESULTS: : Both procedures were found significantly to reduce orbital compartment pressure. Lateral canthotomy and cantholysis was found to lower the pressure by an average of 56 mm Hg as compared with inferior septal release, which resulted in an average of 52-mm Hg reduction. Performing lateral canthotomy and cantholysis first, followed by inferior septal release, resulted in a total pressure reduction of 73 mm Hg, whereas reversing the order resulted in a reduction of 77 mm Hg. Both the first and second steps, regardless of the order of procedure, were found to result in a significant pressure reduction (p = 0.009 and 0.004, respectively). Comparison of a series of data points collected during the induction of the experimental compartment syndrome revealed a statistically significant correlation between orbital compartment pressure and intraocular pressure (Spearman correlation of 0.978 and p value <0.001).
DISCUSSION: : The study demonstrates that both lateral canthotomy/cantholysis and inferior orbital septum release are equally effective at reducing orbital compartment pressure. Additionally, the data support an additive, synergistic reduction in compartment pressure when the procedures are performed consecutively. The correlation of orbital compartment pressure to intraocular pressure proves that intraocular pressure can be used as a reliable measurement of orbital pressure during acute changes in orbital mass. The results of this study demonstrate that the use of inferior orbital septum release in conjunction with lateral canthotomy and cantholysis is superior to the gold standard of isolated lateral canthotomy and cantholysis. We hope that the implementation of orbital septum release will result in superior visual outcomes.
Authors:
Alan E Oester; Brian T Fowler; James C Fleming
Related Documents :
17591059 - Comparison of the effects on cardiopulmonary function of ultrathin transnasal versus no...
8081189 - Effect of arterial pco2 on local hbo2 and relative hb concentration in the human brain-...
10579259 - Beneficial effects of helium:oxygen versus air:oxygen noninvasive pressure support in p...
7678039 - Effects of graded levels of tissue oxygen pressure on dopamine metabolism in the striat...
10963629 - Theoretical simulation of oxygen transport to brain by networks of microvessels: effect...
20076109 - Nature of charge carriers in negative coronas.
1770469 - Blood pressure and heart rate variability in elderly patients with isolated systolic hy...
15818099 - Low spatial resolution computed tomography underestimates lung overinflation resulting ...
8948319 - Secondary hypertension: evaluation and treatment.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Ophthalmic plastic and reconstructive surgery     Volume:  28     ISSN:  1537-2677     ISO Abbreviation:  Ophthal Plast Reconstr Surg     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-01-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8508431     Medline TA:  Ophthal Plast Reconstr Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  40-3     Citation Subset:  IM    
Affiliation:
*Vanderbilt University Medical Center, Nashville; and †Hamilton Eye Institute, University of Tennessee Health Science Center, Memphis, Tennessee, U.S.A.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Silicone intubation for the treatment of epiphora in adults with presumed functional nasolacrimal du...
Next Document:  Normal exophthalmometry measurements in a United States pediatric population.