Infant flow biphasic nasal continuous positive airway pressure (BP- NCPAP) vs. infant flow NCPAP for the facilitation of extubation in infants' ≤ 1,250 grams: a randomized controlled trial.
Jump to Full Text
MedLine Citation:
PMID:  22475409     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: The use of mechanical ventilation is associated with lung injury in preterm infants and therefore the goal is to avoid or minimize its use. To date there is very little consensus on what is considered the "best non-invasive ventilation mode" to be used post-extubation. The objective of this study was to compare the effectiveness of biphasic nasal continuous positive airway pressure (BP-NCPAP) vs. NCPAP in facilitating sustained extubation in infants ≤ 1,250 grams.
METHODS: We performed a randomized controlled trial of BP-NCPAP vs. NCPAP in infants ≤ 1,250 grams extubated for the first time following mechanical ventilation since birth. Infants were extubated using preset criteria or at the discretion of the attending neonatologist. The primary outcome was the incidence of sustained extubation for 7 days. Secondary outcomes included incidence of adverse events and short-term neonatal outcomes.
RESULTS: Sixty-seven infants received BP-NCPAP and 69 NCPAP. Baseline characteristics were similar between groups. The trial was stopped early due to increased use of non-invasive ventilation from birth, falling short of our calculated sample size of 141 infants per group. The incidence of sustained extubation was not statistically different between the BP-NCPAP vs. NCPAP group (67% vs. 58%, P = 0.27). The incidence of adverse events and short-term neonatal outcomes were similar between the two groups (P > 0.05) except for retinopathy of prematurity which was noted to be higher (P = 0.02) in the BP-NCPAP group.
CONCLUSIONS: Biphasic NCPAP may be used to assist in weaning from mechanical ventilation. The effectiveness and safety of BP-NCPAP compared to NCPAP needs to be confirmed in a large multi-center trial as our study conclusions are limited by inadequate sample size. CLINICAL TRIALS REGISTRATION #: NCT00308789 SOURCE OF SUPPORT: Grant # 06-06, Physicians Services Incorporated Foundation, Toronto, Canada. Summit technologies Inc. provided additional NCPAP systems and an unrestricted educational grant.Abstract presented at The Society for Pediatric Research Meeting, Baltimore, USA, May 2nd-5th, 2009 and Canadian Paediatric Society Meeting, June 23rd-29th, Ottawa, 2009.
Authors:
Karel O'Brien; Craig Campbell; Leanne Brown; Lisa Wenger; Vibhuti Shah
Related Documents :
11948979 - Exhaled nitric oxide at school age in prematurely born infants with neonatal chronic lu...
10380089 - Effects of inhaled beclomethasone compared to systemic dexamethasone on lung inflammati...
10351129 - Estimation of pulmonary deposition of aerosol using gamma scintigraphy.
15861169 - Antenatal associations with lung maturation and infection.
9458939 - Oxidation products of uric acid and ascorbic acid in preterm infants with chronic lung ...
12177829 - Ontogeny of the pulmonary surfactant and antioxidant enzyme systems in the viviparous l...
11675159 - Diversity in death certification: a case vignette approach.
10399039 - Aspects of the epizootiology of pancreas disease in farmed atlantic salmon salmo salar ...
9247009 - Sudden infant death syndrome and smoking in the united states and sweden.
Publication Detail:
Type:  Comparative Study; Journal Article; Randomized Controlled Trial; Research Support, Non-U.S. Gov't     Date:  2012-04-04
Journal Detail:
Title:  BMC pediatrics     Volume:  12     ISSN:  1471-2431     ISO Abbreviation:  BMC Pediatr     Publication Date:  2012  
Date Detail:
Created Date:  2012-07-19     Completed Date:  2012-10-15     Revised Date:  2013-06-26    
Medline Journal Info:
Nlm Unique ID:  100967804     Medline TA:  BMC Pediatr     Country:  England    
Other Details:
Languages:  eng     Pagination:  43     Citation Subset:  IM    
Affiliation:
Department of Paediatrics, Mount Sinai Hospital, Toronto, Canada. kobrien@mtsinai.on.ca
Data Bank Information
Bank Name/Acc. No.:
ClinicalTrials.gov/NCT00308789
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Airway Extubation* / statistics & numerical data
Continuous Positive Airway Pressure / adverse effects,  instrumentation,  methods*
Early Termination of Clinical Trials
Female
Humans
Infant, Newborn
Infant, Premature
Infant, Premature, Diseases / epidemiology,  therapy
Infant, Very Low Birth Weight*
Intention to Treat Analysis
Logistic Models
Male
Multivariate Analysis
Outcome Assessment (Health Care)
Ventilator Weaning / methods*
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): BMC Pediatr
Journal ID (iso-abbrev): BMC Pediatr
ISSN: 1471-2431
Publisher: BioMed Central
Article Information
Download PDF
Copyright ©2012 O'Brien et al; licensee BioMed Central Ltd.
open-access:
Received Day: 31 Month: 5 Year: 2011
Accepted Day: 4 Month: 4 Year: 2012
collection publication date: Year: 2012
Electronic publication date: Day: 4 Month: 4 Year: 2012
Volume: 12First Page: 43 Last Page: 43
ID: 3402979
Publisher Id: 1471-2431-12-43
PubMed Id: 22475409
DOI: 10.1186/1471-2431-12-43

Infant flow biphasic nasal continuous positive airway pressure (BP- NCPAP) vs. infant flow NCPAP for the facilitation of extubation in infants' ≤ 1,250 grams: a randomized controlled trial
Karel O'Brien12 Email: kobrien@mtsinai.on.ca
Craig Campbell3 Email: craig.campbell@sickkids.ca
Leanne Brown4 Email: lhavlin@mtsinai.on.ca
Lisa Wenger4 Email: LWenger@mtsinai.on.ca
Vibhuti Shah12 Email: vshah@mtsinai.on.ca
1Department of Paediatrics, Mount Sinai Hospital, Toronto, Canada
2Department of Paediatrics, University of Toronto, Toronto, Canada
3Department of Respiratory Therapy, The Hospital for Sick Children, Toronto, Canada
4Department of Respiratory Therapy, Mount Sinai Hospital, Toronto, Canada

Background

With advances in neonatal care, > 85% of infants with birth weight < 1,500 grams now survive [1,2]. Parallel to this improved survival is the increase in the incidence of bronchopulmonary dysplasia (BPD). In 2001, the National Institute of Child Health and Human Development Neonatal Research Network reported an incidence of BPD of up to 40% in infants < 1,000 grams [1] while the incidence of BPD was reported to be 21.4% (inter-quartile range 12.5%, 30.6%) for infants born between 501-1,500 grams in 750 neonatal intensive care units (NICUs) participating in the Vermont Oxford Network for the year 2008 [3]. Similarly in Europe, the incidence of BPD was 19.6% for the year 2006 among 60 NICUs participating in the EuroNeoNet [4]. Recently in 2010, Finer et al reported the incidence of BPD to be as high as 44% for infants born between 240/7 to 276/7 weeks gestation [5].

Bronchopulmonary dysplasia is a multi-factorial condition with interplay of antenatal, genetic and environmental factors. Central to its pathogenesis are lung immaturity and the use of mechanical ventilation [6]. It has been hypothesized that earlier extubation and use of nasal continuous positive airway pressure (NCPAP) may decrease lung inflammation and reduce the incidence of BPD [7]. It may also reduce ventilator-associated pneumonia and necrotizing tracheitis. Further, baboon studies suggest that the early use of CPAP may mitigate the decreased brain growth and cerebral neuropathologies seen in preterm infants who require ventilation [8]. Supporting evidence in human neonates comes from the results of the caffeine for apnea of prematurity trial where the investigators demonstrated that a reduction in the duration of positive pressure ventilation (of 1 week) [9] through an endotracheal tube was associated with an improved rate of survival without neuro-developmental disability (reduced rate of cerebral palsy and cognitive delay) [10].

The Infant Flow™ System (Viasys Healthcare Inc, Yorba Linda, CA, USA) used in our study is the most widely utilized variable flow device. It uses high velocity jet flows that can entrain gas on demand during inspiration and therefore keep the CPAP level constant. On exhalation the design of the nasal prongs results in some of the fresh gas being shunted away through an expiratory outlet rather than continuing to the nares reducing the expiratory work [11-14]. In contrast to regular NCPAP which provides a continuous distending pressure, biphasic NCPAP (BP-NCPAP) cycles between upper and lower (baseline) level pressures as determined by the following four parameters a) lower CPAP level b) upper CPAP level c) time at upper level and d) rate (cycles/minute at upper level). Theoretically, functional residual capacity is recruited by the upper CPAP level and maintained with the lower baseline CPAP level, thus decreasing the work of breathing. To date there have been no studies comparing the use of these two modes of non-invasive ventilation in preterm infants to facilitate sustained extubation following an initial period of intubation and positive pressure ventilation at birth.

The primary goal of this study was to compare the effectiveness of BP-NCPAP vs. NCPAP using the Infant Flow® SiPAP™ Viasys Healthcare Inc. system in facilitating sustained extubation in preterm infants ≤ 1,250 grams. The secondary goals were to compare the adverse events and short-term neonatal morbidities between the two groups.


Methods

In this randomized controlled trial we included intubated infants with birth weight ≤ 1,250 grams. Infants with congenital abnormalities of the upper airway tract, acquired nasal septum injury and major congenital or chromosomal abnormalities were excluded. The study was conducted at a tertiary care NICU, Mount Sinai Hospital, Toronto, Ontario, Canada, during the period from April 2006 to November 2008.

Parents of eligible infants were approached for participation in the trial and written informed consent was obtained prior to extubation. A marker was then placed at the bedside of eligible infants whose parents had given consent. Randomization cards were generated using a computer generated random numbers list. The cards were sealed in sequentially marked opaque envelopes and opened immediately prior to the first extubation. Infants were randomized to one of two groups: BP-NCPAP or NCPAP delivered by the Infant Flow® SiPAP™ (Viasys Healthcare, Yorba Linda, CA, USA). The assigned mode of support was continued until the infant was ready to be placed in room air or supplemental oxygen. The study was approved by the local Research Ethics Board.

Preset criteria were used to guide extubation using a consensus approach amongst neonatologists in our NICU. For conventional ventilation the criteria included: a ventilator rate of < 20 breaths per minute (bpm), peak inspiratory pressure (PIP) ≤ 16 cm H2O and fractional inspired oxygen (FiO2) of ≤ 0.35. For high frequency ventilation the criteria were: frequency of 9-13 Hz, amplitude < 20 percent, mean airway pressure (MAP) of ≤ 8 cm H2O and FiO2 ≤ 0.35. Once an infant reached these preset criteria, the medical team was approached for consideration of extubation. In the event of accidental extubation in eligible consented infants, face mask CPAP was applied for no more than 15 minutes until a decision was made either to reintubate based on the clinical condition or to randomize to the study group. All infants had the appropriate bonnet, nasal prong interface and Cannulaide® (Beevers Manufacturing Inc., McMinnville, OR, USA) applied.

In the BP-NCPAP arm the respiratory rate was set at 20 bpm with an inspiratory time of 1.0 second. The upper level of CPAP was set 3 cm above the lower (baseline) level of CPAP. In both modes the lowest baseline CPAP was set at 5 cm H2O and the CPAP was titrated according to the infant's FiO2 needs based on an algorithm (Table 1). Neither mode of NCPAP was synchronised with the infant's respiratory effort. Weaning in both groups was left at the discretion of the attending neonatologist. If the infant remained clinically stable in FiO2 ≤ 0.25 with no evidence of increased work of breathing and/or apnea of prematurity, then attempt was made to trial off CPAP.

Criteria for reintubation included: presence of severe apnea (defined as need for positive pressure ventilation), ≥ 4 minor apneic episodes per hour requiring moderate stimulation, required supplemental oxygen of > 60% to maintain oxygen saturation > 88%, developed uncompensated respiratory acidosis (defined a pH < 7.25) or a combination of the above. Apnea was defined as cessation of respiration for > 20 seconds or a shorter pause if associated with bradycardia (heart rate < 100 beats per minute) or desaturation (< 85%). Reintubation was also allowed at the discretion of the attending medical team for other reasons, e.g., concerns regarding sepsis. Data were collected for the duration of their in-hospital stay. Other medical therapy and interventions were provided at the discretion of the medical team.

In our unit, caffeine is usually commenced in the first week of life even if the infant requires positive pressure ventilation via endotracheal tube. A loading dose of 10 mg/kg followed by maintenance dose of 2.5 mg/kg is administered within 24-36 hours. Based on the clinical response the maximum dose of maintenance caffeine used is 5 mg/kg.

Data were collected on maternal characteristics including age, gravidity, parity, pregnancy induced hypertension, essential hypertension, preterm prolonged rupture of the membranes (> 18 hours), antenatal steroids (complete and partial course), and clinical and histological diagnosis of chorioamnionitis from maternal health records and placental pathology.

The primary outcome was the incidence of sustained extubation for 7 days. Secondary outcomes included incidence of adverse events such as: nasal septal injury/erythema, eyelid edema, abdominal distension, feeding intolerance and pneumothorax. Nasal septal injury/erythema and eyelid edema were monitored and recorded every 4 hours by the respiratory therapists and the nursing staff. Data on feeding intolerance (defined as aspirates of ≥ 30% of a single feed administered) and abdominal distension (defined as > 10% increase in abdominal girth) were recorded by the nursing staff every 4 hours and/or prompted by clinical concerns. Data on the other clinical outcomes including the incidence of BPD [oxygen dependency at 36 weeks post menstrual age (PMA)], patent ductus arteriosus (PDA) (diagnosed clinically or by ECHO and treated with indomethacin ± surgery), necrotizing enterocolitis (NEC) (Bell's stage 2 or greater) [15], grade 3/4 intraventricular hemorrhage (IVH) [16] or periventricular leucomalacia (PVL) and retinopathy of prematurity (ROP) were abstracted from the chart. Retinopathy of prematurity was classified according to the international classification [17]. Infants who died were excluded from the analysis for ROP and for BPD if they died before they reached 36 weeks PMA. In our unit, PDA is treated pharmacologically (with indomethacin) based on the presence of clinical symptoms and signs. Prior to administration of a second course of indomethacin or referral for surgical ligation, infants undergo echocardiography. Both caregivers administering the interventions and research assistants were not blinded to the group assignment.

The sample size calculation was based on the results obtained from a previous study that compared the rate of sustained extubation using NCPAP vs. high flow oxygen in our unit. The rate of sustained extubation with NCPAP was 85% [18]. To demonstrate a clinically significant increase in the rate of sustained extubation by 10% between groups (i.e. from 85% to 93.5%) with 80% power and an alpha value of 0.05, we estimated a sample size of 141 patients in each arm for a total of 282 patients.

The analysis was performed using the intention-to-treat principle. Baseline maternal and infant characteristics and outcomes of the infants randomized to both modes were compared using χ2 test for categorical data and Student's t test for continuous data. The Wilcoxon rank sum test was used to compare continuous data with highly skewed distributions. All reported P values are two sided. A planned secondary analysis examined the predictors of successful extubation using multivariate logistic regression to control for possible confounders including birth weight, sex, age at the time of first extubation, accidental extubation and use of antenatal steroids. All statistical analyses were performed using the computer program Statistical Package for the Social Sciences v.12™ (Chicago, IL, USA). A P value of 0.05 was considered significant.


Results

Of the 534 infants ≤ 1,250 grams admitted to the NICU during the study period, 348 infants were eligible for the study. Parents of 190 infants were approached of whom 43 declined and 147 consented. Four infants died and 7 were transferred to another site prior to randomization. Thus, a total of 136 neonates were enrolled (Figure 1). The trial had to be stopped prematurely prior to enrolment of the intended sample size due to a change in clinical practice in our unit that resulted in fewer infants being intubated from birth. Results are presented for the recruited subjects. No interim analysis was performed.

The demographic characteristics (birth weight, gestational age and sex) did not differ between participants and non-participants. Sixty-seven infants were randomized to BP-NCPAP and 69 to NCPAP. Baseline maternal and neonatal characteristics of the participants are presented in Tables 2 and 3, respectively. There were no significant differences between the two groups.

The incidence of sustained extubation following the first extubation was 67% (45/67) in the BP-NCPAP group compared with 58% (40/69) in the NCPAP group (P = 0.27). The reasons and time for reintubation in the first 7 days following extubation are presented in Table 4. The incidence of adverse events and short-term neonatal outcomes were similar between groups except for ROP which was higher in the BP-NCPAP group (P = 0.02) (Table 5). No infant developed pneumothorax following extubation with either mode.

Multivariate regression analysis identified that birth weight was the most important predictor of sustained extubation (P = 0.003) regardless of the mode of CPAP used (Table 6). For every 100 grams increase in birth weight the odds of a successful outcome was 1.49 times higher.


Discussion

In our study, we were unable to demonstrate the effectiveness of BP-NCPAP in facilitating sustained extubation. Further, the incidence of adverse events, reasons for reintubation and short-term neonatal morbidities except for ROP were similar in both groups. There may be several reasons for our inability to show a difference in the primary outcome. Firstly, we were unable to recruit the predetermined sample size to demonstrate a difference due to increasing use of non-invasive ventilation from birth. This is a major flaw of our study. Secondly, the overall rate of sustained extubation in our infants was much lower than anticipated. The rate of sustained extubation in our study ranged from 58% to 67% compared to a rate of 85% used to determine our sample size. Using these revised rates of sustained extubation and an effect size of 10%, we would need to recruit a total of 870 infants to demonstrate a difference. Obviously conducting such a trial requires a collaborative effort and is a major undertaking.

Our a priori hypothesis was to demonstrate/achieve a clinically significant increase in the rate of sustained extubation of 10% with the use of BP-NCPAP. With our limited sample size we were able to demonstrate an increase in the rate of sustained extubation by 9% in the BP-NCPAP group even though this difference was not statistically significant. We cannot rule out the possibility that if we had indeed achieved our targeted sample size we may have been able shown a statistically significant difference. In clinical practice, this difference of 9% may be considered clinically significant as there is increasing trend of using non-invasive ventilation to avoid the consequences of mechanical ventilation.

To our knowledge, there are no previous published studies that have evaluated BP-NCPAP for facilitating successful sustained extubation following intubation and ventilation at birth, i.e., used as a secondary mode. The trial was initiated at our site when infants ≤ 1,250 grams were routinely intubated and ventilated at birth and administered prophylactic surfactant if ≤ 27 weeks gestation. Biphasic-NCPAP is considered a form of nasal intermittent positive pressure ventilation (NIPPV) and therefore we compared the results of our study to those of NIPPV when used as a secondary mode. In an updated Cochrane review in 2008, Davis et al. [19] compared NIPPV vs. CPAP for preterm infants after extubation. They demonstrated a reduction in extubation failure rate [relative risk (RR) 0.39; 95% confidence interval (CI) 0.16, 0.97)] with the use of synchronized NIPPV (data from 3 trials with N = 159) and concluded that it may potentially be a way of augmenting NCPAP when used to prevent extubation failure. Further evidence that NIPPV facilitates successful extubation comes from a recent randomized controlled trial by Moretti et al. [20] in which 94% (30/32) of infants in the NIPPV group were successfully extubated (defined as no reintubation within 3 days) compared with 61% (19/31) in the NCPAP group (P = 0.01). The details of the 4 published trials on NIPPV are presented in Table 7.

The above findings are in contrast to the results of our study. Possible explanations for the difference in the effectiveness of NIPPV compared to BP-NCPAP include variations in the: 1) definition of sustained extubation, 2) the median age of extubation and 3) ventilatory parameters used to prevent reintubation. The duration of successful extubation in the NIPPV trials was defined as 48 hours [21] to 72 hours [20,22,23] vs. 7 days in our study. Further, the median age of extubation was day 3 in our study vs. 7 days [22,23] and 18.5-21 days [21] in the NIPPV studies. This later age of extubation may have resulted in resolution of co-morbidities such as a clinically significant patent ductus arteriosus in the first 7-10 days, which could contribute to successful sustained extubation.

As BP-NCPAP is considered to be a form of NIPPV, we conducted a meta-analysis including data from the 4 published studies and our results (Figure 2). The incidence of extubation failure was lower with the use of NIPPV and BP-NCPAP compared to NCPAP [Relative risk (RR), 0.27; 95% confidence interval (CI), 0.17, 0.43; P < 0.01]. No significant statistical heterogeneity was noted for this outcome. The risk difference was -0.30, 95% CI (-0.38, -0.21; P < 0.01). The number needed to prevent one infant from being reintubated was 3 (95% CI, 2, 5).

When we designed our study, there were no previous studies to guide us in our choice of ventilatory parameters to be used to provide effective BP-NCPAP. The maximum upper level of CPAP that can be set with BP-NCPAP is less than that used for NIPPV and with the use of endotracheal tube and ventilation. In our study, the upper level of CPAP varied from 8 to 10 cmH2O based on the oxygen requirements of the infant. The inspiratory and expiratory time were set at 1.0 and 2.0 seconds respectively resulting in a pressure exchange rate of 20 breaths per minute (cycle/minute at upper level). We were unable to synchronize the delivery of the upper level of CPAP with this device. The combination of lack of synchronization with low pressure exchange rate and upper level of CPAP may have been critical factors contributing to our failure in facilitating sustained extubation. With most modes of NCPAP or indeed NIPPV synchronisation is imperfect, using either a Graseby capsule on the infant's abdomen or most recently a flow detector at the nares [24]. When a higher rate of ventilation is used as in most modes of NIPPV then synchronisation happens more often just by chance. Synchronisation may be important for entrainment of tidal volumes both on inspiration and expiration [24-26] and that this may in part explain the clinical benefit of synchronised NIPPV.

Recently, BP-NCPAP has been evaluated for infants with moderate respiratory distress syndrome as a primary mode of ventilation. Infants between 28-34 weeks gestation were randomized to either BP-NCPAP or NCPAP in the first hour of birth. The use of BP-NCPAP was associated with shorter respiratory support and oxygen dependency with no difference in the rate of reintubation [27]. In the BP-NCPAP group; the investigators used a pressure exchange rate of 30 bpm, inspiratory time of 0.5-0.7 seconds and upper and lower CPAP level of 8 and 4.5 cm H2O respectively.

Adverse events such as increased risk of pneumothorax, nasal septal trauma, feeding intolerance, abdominal distension and gram-negative sepsis secondary to nasal mucosal barrier breakdown have been described in the literature with the use of various forms of NCPAP [5,28,29]. The incidence of pneumothorax was reported to be 6.8% [5] and 9% [29] respectively in the Support and the COIN trial where NCPAP was used soon after birth. We did not find any increase in the risk of pneumothorax in our trial. One major difference between the previous studies and ours is that we used NCPAP after the first extubation rather than using it as a primary mode of ventilation. Increased risk of gastric perforation has been reported with the use of NIPPV [30]. No differences in the rate of short-term neonatal morbidities, especially BPD were noted between groups in our study. We did find an increased risk of ROP in the BP-NCPAP compared to NCPAP group (P = 0.02). It is important to recognize that our study was not powered to detect differences in these secondary outcomes so the finding of increased incidence of ROP needs to be confirmed/refuted in future studies.


Conclusion

BP-NCPAP may be used safely and effectively to assist in weaning from mechanical ventilation. However, the effectiveness and safety of BP-NCPAP compared to NCPAP needs to be confirmed in a large multi-center trial as our study conclusions are limited by inadequate sample size.


Competing interests

The authors declare that they have no competing interests.


Authors' contributions

KOB conceived the study, participated in designing the study, assisted in data collection and participated in the checking, analysis and interpretation of the data and drafting the manuscript. CC conceived the study, participated in designing the study, recruited patients, assisted in data collection and in the checking, analyzing and interpretation of the data, and drafting of the manuscript. Both LH and LW participated in the recruitment of study patients, collected data and had input in drafting of the manuscript. VS contributed to the design of the study, participated in the checking, analysis and interpretation of the data and in drafting of the manuscript. All authors have read and approved the final manuscript.


Pre-publication history

The pre-publication history for this paper can be accessed here:

http://www.biomedcentral.com/1471-2431/12/43/prepub


Acknowledgements

We acknowledge the support of Woojin Yoon, Statistician, MiCare Research Center at Mount Sinai Hospital Toronto. We acknowledge the Ontario Ministry of Health and Long-Term Care for providing financial support to the MiCare Research Center at Mount Sinai Hospital, Toronto, Ontario.


References
Lemons JA,Bauer CR,Oh W,Korones SB,Papile LA,Stoll BJ,Verter J,Temprosa M,Wright LL,Ehrenkranz RA,Fanaroff AA,Stark A,Carlo W,Tyson JE,Donovan EF,Shankaran S,Stevenson DK,Very low birth weight outcomes of the National Institute of Child health and human development neonatal research network, January 1995 through December 1996PediatricsYear: 2001107E110.1542/peds.107.1.e111134465
Jones HP,Karuri S,Cronin CM,Ohlsson A,Peliowski A,Synnes A,Lee SK,Canadian Neonatal Network: Actuarial survival of a large Canadian cohort of preterm infantsBMC PediatrYear: 200554010.1186/1471-2431-5-4016280080
Horbar JD,Soll RF,Edwards WH,The Vermont Oxford Network: a community of practiceClin PerinatolYear: 201037294710.1016/j.clp.2010.01.00320363446
European Perinatal Health ReportYear: 2008http://www.europeristat.com
SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research NetworkFiner NN,Carlo WA,Walsh MC,Rich W,Gantz MG,Laptook AR,Yoder BA,Faix RG,Das A,Poole WK,Donovan EF,Newman NS,Ambalavanan N,Frantz ID,Buchter S,Sánchez PJ,Kennedy KA,Laroia N,Poindexter BB,Cotten CM,Van Meurs KP,Duara S,Narendran V,Sood BG,O'Shea TM,Bell EF,Bhandari V,Watterberg KL,Higgins RD,Early CPAP versus surfactant in extremely preterm infantsN Engl J MedYear: 20103621970197920472939
Coalson JJ,Winter VT,Siler-Khodr T,Yoder BA,Neonatal chronic lung disease in extremely immature baboonsAm J Respir Crit Care MedYear: 19991601333134610508826
Morley CJ,Davis PG,Continuous positive airway pressure: scientific and clinical rationaleCurr Opin PediatrYear: 20082011912410.1097/MOP.0b013e3282f6395318332704
Loeliger M,Inder T,Cain S,Ramesh RC,Camm E,Thomson MA,Coalson J,Rees SM,Cerebral outcomes in a preterm baboon model of early versus delayed nasal continuous positive airway pressurePediatricsYear: 20061181640165310.1542/peds.2006-065317015557
Schmidt B,Roberts RS,Davis P,Doyle LW,Barrington KJ,Ohlsson A,Solimano A,Tin W,Caffeine for Apnea of Prematurity Trial Group: Caffeine therapy for apnea of prematurityN Engl J MedYear: 20063542112212110.1056/NEJMoa05406516707748
Schmidt B,Roberts RS,Davis P,Doyle LW,Barrington KJ,Ohlsson A,Solimano A,Tin W,Caffeine for Apnea of Prematurity Trial GroupLong-term effects of caffeine therapy for apnea of prematurityN Engl J Med
Klausner JF,Lee AY,Hutchison AA,Decreased imposed work with a new nasal continuous positive airway pressure devicePediatr PulmonolYear: 19962218819410.1002/(SICI)1099-0496(199609)22:3<188::AID-PPUL8>3.0.CO;2-L8893258
Courtney SE,Pyon KH,Saslow JG,Arnold GK,Pandit PB,Habib RH,Lung recruitment and breathing pattern during variable versus continuous flow nasal continuous positive airway pressure in premature infants: an evaluation of three devicesPediatricsYear: 200110730430810.1542/peds.107.2.30411158463
Pandit PB,Courtney SE,Pyon KH,Saslow JG,Habib RH,Work of breathing during constant- and variable-flow nasal continuous positive airway pressure in preterm neonatesPediatricsYear: 200110868268510.1542/peds.108.3.68211533336
Boumecid H,Rakza T,Abazine A,Klosowski S,Matran R,Storme L,Influence of three nasal continuous positive airway pressure devices on breathing pattern in preterm infantsArch Dis Child Fetal Neonatal EdYear: 200792F298F30010.1136/adc.2006.10376217088340
Bell MJ,Ternberg JL,Feigin RD,Keating JP,Marshall R,Barton L,Brotherton T,Neonatal necrotizing enterocolitis. Therapeutic decisions based upon clinical stagingAnn SurgYear: 19781871710.1097/00000658-197801000-00001413500
Papile LA,Burstein J,Burstein R,Koffler H,Incidence and evaluation of subependymal and intraventricular hemorrhage: a study of infants with birth weight less than 1,500 gramsJ PediatrYear: 19789252953410.1016/S0022-3476(78)80282-0305471
International committee for the classification of retinopathy of prematurityThe International classification of retinopathy of prematurity revisitedArch OphthalmolYear: 200512399199916009843
Campbell DM,Shah PS,Shah V,Kelly EN,Nasal continuous positive airway pressure from high flow cannula versus Infant Flow for Preterm infantsJ PerinatolYear: 20062654654910.1038/sj.jp.721156116837929
Davis PG,Lemyre B,De Paoli AG,Nasal intermittent positive pressure ventilation (NIPPV) versus nasal continuous positive airway pressure (NCPAP) for preterm neonates after extubationCochrane Database Syst RevYear: 20013CD00321211687052
Moretti C,Giannini L,Fassi C,Gizzi C,Papoff P,Colarizi P,Nasal flow-synchronized intermittent positive pressure ventilation to facilitate weaning in very low-birthweight infants: unmasked randomized controlled trialPediatr IntYear: 200850859110.1111/j.1442-200X.2007.02525.x18279212
Friedlich P,Lecart C,Posen R,Ramicone E,Chan L,Ramanathan R,A randomized trial of nasopharyngeal-synchronized intermittent mandatory ventilation versus nasopharyngeal continuous positive airway pressure in very low birth weight infants after extubationJ PerinatolYear: 19991941341810.1038/sj.jp.720020510685270
Barrington KJ,Bull D,Finer NN,Randomized trial of nasal synchronized intermittent mandatory ventilation compared with continuous positive airway pressure after extubation of very low birth weight infantsPediatricsYear: 200110763864110.1542/peds.107.4.63811335736
Khalaf MN,Brodsky N,Hurley J,Bhandari V,A prospective randomized, controlled trial comparing synchronized nasal intermittent positive pressure ventilation versus nasal continuous positive airway pressure as modes of extubationPediatricsYear: 2001108131710.1542/peds.108.1.1311433048
Moretti C,Gizzi C,Papoff P,Lampariello S,Capoferri M,Calcagnini G,Bucci G,Comparing the effects of nasal synchronized intermittent positive pressure ventilation (nSIPPV) and nasal continuous positive airway pressure (nCPAP) after extubation in very low birth weight infantsEarly Hum DevYear: 19995616717710.1016/S0378-3782(99)00046-810636595
Owen LS,Morley CJ,Davis PG,Neonatal nasal intermittent positive pressure ventilation: what do we know in 2007?Arch Dis Child Fetal Neonatal EdYear: 200792F414F41810.1136/adc.2007.11761417712191
Greenough A,Respiratory support techniques for prematurely born infants: new advances and perspectivesActa Paediatr TaiwanYear: 20014220120611550407
Lista G,Castoldui F,Fontana P,Danielle I,Cavigioli F,Rossi S,Mancuso D,Reali R,Nasal continuous airway pressure (CPAP) versus bi-level nasal CPAP in preterm babies with respiratory distress syndrome: a randomised controlled trialArch Dis Child Fetal Neonatal EdYear: 201095F85F8910.1136/adc.2009.16921919948523
Shanmugananda K,Rawal J,Nasal trauma due to nasal continuous positive airway pressure in newbornsArch Dis Child Fetal Neonatal EdYear: 200792F1810.1136/adc.2006.09503417185425
Morley CJ,Davis PG,Doyle LW,Brion LP,Hascoet JM,Carlin JB,Nasal CPAP or intubation at birth for very preterm infantsN Engl J MedYear: 200835870070810.1056/NEJMoa07278818272893
Garland JS,Nelson DB,Rice T,Neu J,Increased risk of gastrointestinal perforations in neonates mechanically ventilated with either face mask or nasal prongsPediatricsYear: 1985764064104034300

Figures

[Figure ID: F1]
Figure 1 

Flow diagram of study participants.



[Figure ID: F2]
Figure 2 

Comparison of the effectiveness of NIPPV vs. NCPAP to prevent extubation failure.



Tables
[TableWrap ID: T1] Table 1 

Guidelines for use of biphasic nasal continuous positive airway pressure (BP-NCPAP) and nasal continuous positive airway pressure (NCPAP)


Settings for BP- NCPAP FiO2* (%) < 0.30 0.30 - 0.50 > 0.50

Upper CPAP
(cm H2O)
8 9 10

Lower CPAP
(cm H2O)
5 6 7
Settings for NCPAP FiO2 (%) < 0.30 0.30 - 0.50 > 0.50

CPAP
(cm H2O)
5 6 7

*FiO2 = Fraction of inspired oxygen


[TableWrap ID: T2] Table 2 

Baseline maternal characteristics


Variable* BP-NCPAP
(N = 63)
NCPAP
(N = 65)
P value
Maternal age (years) [Mean (SD)] 31.5 (6.3) 30.8 (5.9) 0.55

Gravida [Median (IQR)] 2 (1, 3) 2 (1, 3) 0.89

Parity [Median (IQR)] 0 (0, 1) 0 (0, 1) 0.97

Pregnancy induced hypertension/eclampsia [N (%)] 13 (21%) 17 (26%) 0.46

Essential hypertension [N (%)] 8 (13%) 8 (12%) 0.89

Prolonged rupture of membranes [N (%)] 20 (32%) 25 (38%) 0.42

Chorioamnionitis [N (%)]
Clinical 9 (14%) 15 (23%) 0.20
Histological 29 (52%) 26 (43%) 0.32

Antenatal steroid [N (%)]
Complete course 42 (67%) 47 (72%) 0.35
Partial course 11 (17%) 13 (20%)
None 10 (16%) 5 (8%)

*IQR = Inter-quartile range, N = Number, % = Percent, SD = Standard deviation


[TableWrap ID: T3] Table 3 

Baseline characteristics of the study participants


Variable* BP-NCPAP
(N = 67)
NCPAP
(N = 69)
P value
Gestational age (weeks) [Mean (SD)] 27.3 ± 1.9 27.4 ± 1.7 0.60

Birth weight (grams) [Mean (SD)] 901 ± 200 896 ± 156 0.86

Male [N (%)] 39 (58%) 31 (44%) 0.13

Apgar score (1 minute) [Median (IQR)] 5 (3, 7) 5 (2, 7) 0.56

Apgar score (5 minutes) [Median (IQR)] 8 (7, 9) 8 (7, 9) 0.63

Mode of ventilation [N (%)]
IPPV 50 (75%) 51 (74%) 0.85
HFOV 14 (21%) 16 (23%)
HFJV 3 (4%) 2 (3%)

Age at first extubation (days) [Median (IQR)] 3 (1-67) 3 (1-62) 0.85

Time of blood gas prior to extubation (hours) [Median (IQR)] 9 (5, 14) 7 (5, 12) 0.15

Blood gas prior to extubation [Mean (SD)]

pH 7.3 ± 0.1 7.3 ± 0.1 0.12

PCO2 47.1 ± 11.0 48.5 ± 10.9 0.48

FiO2 [Mean (SD)] 0.24 ± 0.06 0.26 ± 0.08 0.40

Fulfilled preset extubation criteria [N (%)] 47 (70%) 55 (80%) 0.20

Accidental extubation in infants who did not meet preset extubation criteria [N (%)] 6 (9%) 7 (10%) 0.98

Surfactant administration [N (%)] 61 (91%) 66 (96%) 0.32

Caffeine administration [N (%)] 65 (97%) 64 (92%) 0.44

*FiO2 = Fraction of inspired oxygen, HFJV = High frequency jet ventilation, HFOV = High frequency oscillatory ventilation, IPPV = Intermittent positive pressure ventilation, IQR = Inter-quartile range, N = Number, % = Percent, SD = Standard deviation


[TableWrap ID: T4] Table 4 

Comparison of primary outcome and extubation characteristics


Variable* BP-NCPAP
(N = 67)
NCPAP
(N = 69)
P value
Successful extubation [N (%)] 45 (67%) 40 (58%) 0.27

Time of blood gas after extubation (hours) [Median (IQR)] 4 (2, 6) 2 (2, 4) 0.02

Blood gas after extubation [Mean (SD)]
pH 7.4 ± 0.1 7.3 ± 0.1 0.02
PCO2 45.8 ± 13.4 47.8 ± 13.3 0.39

FiO2 [Mean (SD)] 0.27 ± 0.09 0.26 ± 0.06 0.30

Time to reintubation (days) [Median (IQR)] 2 (1, 4) 1 (1, 5) 0.76

Number and reasons for reintubation [N (%)] N = 22 N = 29
Hypercapnia 0 0
FiO2 requirements > 60% 2 (9%) 0 0.14
Severe apnea defined as need for positive pressureventilation or frequent apnea defined as ≥ 4 minor apneic episodes per hour requiring moderate stimulation 13 (59%) 23 (79%)
Combination of the above 7 (32%) 6 (21%)

*FiO2 = Fraction of inspired oxygen, IQR = Inter-quartile range, N = Number, % = Percent, SD = Standard deviation


[TableWrap ID: T5] Table 5 

Incidence of adverse events and short-term neonatal outcomes


Variable* BP-NCPAP
(N = 67)
NCPAP
(N = 69)
P value
Adverse events

Nasal septum breakdown [N (%)] 6 (8.9%) 9 (13%) 0.59

Eyelid edema [N (%)] 3 (4.5%) 2 (2.8%) 0.68

Feeding intolerance [N (%)] 8 (11.9%) 17 (25%) 0.08

Abdominal distension [N (%)] 16 (23.8%) 8 (12%) 0.07

Pneumothorax [N (%)] 0 0

Short-term neonatal outcomes

Mortality [N (%)] 3 (4%) 5 (7%) 0.49

New-onset sepsis after extubation [N (%)] 8 (12%) 5 (7%) 0.35

Bronchopulmonary dysplasia (oxygen dependency at 36 weeks PMA) [N (%)] 21 (31.3%) 22 (31.8%) 1.0

Necrotising enterocolitis [N (%)] 7 (10.4%) 7 (10.1%) 0.95

Grade 3/4 IVH/PVL 1/62 (1.6%) 5/65(7.7%) 0.41

ROP > stage 2 [N (%)] 11 (17%) 3 (5%) 0.02

Patent ductus arteriosus [N (%)] 36 (53.7%) 35 (51%) 0.82

*IVH = Intraventricular hemorrhage, N = Number, % = Percent, PVL = Periventricular leucomalacia, ROP = Retinopathy of prematurity


[TableWrap ID: T6] Table 6 

Predictors of successful extubation


Variable* Odds Ratio (95% CI) P value
Mode of CPAP 1.51 (0.71, 3.20) 0.28

Birth weight in increments of 100 grams 1.49 (1.11, 1.82) 0.003

Female 1.84 (0.87, 3.92) 0.11

Antenatal steroids 1.01 (0.98, 1.05) 0.47

Age at time of first extubation 0.31 (0.08, 1.32) 0.11

Accidental extubation 0.81 (0.30, 2.14) 0.67

* CPAP = Continuous positive airway pressure, CI = Confidence interval


[TableWrap ID: T7] Table 7 

Review of the literature on nasal intermittent positive pressure ventilation (NIPPV) vs. nasal continuous positive airway pressure (NCPAP) for preventing extubation failure


Study author, Year Inclusion criteria Intervention
group
Control
group
Primary outcome Results
Barrington
2001
BW < 1,251 grams
PNA < 6 wks
NSIMV
(N = 27)
NCPAP
(N = 27)
Extubation failure at 72 hours 4/27 (14%) vs. 12/27 (44%) in the NSIMV vs. NCPAP (P < 0.05)
Median age at extubation (range)
3 (1, 29) vs. 3 (1, 40) days

Friedlich 1999 BW 500-1,500 grams NP-SIMV (N = 22) NCPAP (N = 19) Respiratory failure at
48 hours
1/22 (5%) vs.7/19 (37%) in the NP-SIMV vs. NCPAP group
(P = 0.016)
Median age at extubation (range) 18.5 (1, 120) vs. 21(1, 54) days

Khalaf 2001 GA ≤ 34 weeks, RDS SNIPPV (N = 34) NCPAP (N = 30) Remained extubated at 72 hours 32/34 (94%) vs. 18/30 (60%) in the SNIPPV vs. NCPAP group
(P < 0.01)
Median age at extubation (range) 4 (1, 83) vs. 2.5 (1, 106) days

Morretti
2008
BW < 1,251 grams
PNA < 14 days
NFSIPPV (N = 32) NCPAP
(N = 31)
Remained extubated at 72 hours 30/32 (94%) vs. 19/31(61%) in the
NFSIPPV vs. NCPAP (P < 0.01)
Median age at extubation (range)
4 (1, 14) vs. 6 (1, 14) days

*BW = Birth weight, CPAP = Continuous positive airway pressure, GA = Gestational age, NCPAP = Nasal continuous positive airway pressure, NSIMV = Nasal synchronized intermittent mandatory ventilation, NFSIPPV = Nasal flow synchronized intermittent positive pressure ventilation, PNA = Post natal age, SNIPPV = Synchronized nasal intermittent positive pressure ventilation



Article Categories:
  • Research Article

Keywords: Infant-newborn, Non-invasive ventilation, Continuous positive airway pressure, Extubation failure.

Previous Document:  The "knucklehead" approach and what matters in terms of health for formerly incarcerated Latino men.