| Increased intraosseous temperature caused by ultrasonic devices during bone surgery and the influences of working pressure and cooling irrigation. | |
| | |
MedLine Citation:
|
PMID: 23189287 Owner: NLM Status: In-Data-Review |
Abstract/OtherAbstract:
|
Purpose: The purpose of this study was to investigate the increases in intraosseous temperature generated by a modern ultrasonic device for bone surgery (UDBS) and the influences of working pressure and cooling irrigation on this temperature. Materials and Methods: Twenty human mandibular bone specimens (20 x 15 x 5 to 7 mm) were used; three vertical cuts were performed for a duration of 12 seconds per cut. Each bone specimen was machined with a different combination of working pressure (1.5, 2.0, 3.0, 4.0, or 6.0 N) and cooling irrigation (0, 30, 60, or 90 mL/min), and intraosseous temperatures were measured. Harmful temperature development was defined as an increase of more than 10°C for the 75th percentile and/or a maximum increase of more than 15°C. Cutting performance was also measured. Results: Harmless intraosseous temperature development was identified for working pressures of 1.5 N and 2.0 N with cooling irrigations of 30, 60, and 90 mL/min and for 3.0 N at 90 mL/min. The maximum temperature observed was 72°C (6.0 N with 60 mL/min). The mean cutting performance values were 0.21 ± 0.02 mm/s for 6.0 N, 0.21 ± 0.06 mm/s for 3.0 N, 0.20 ± 0.01 mm/s for 4.0 N, 0.11 ± 0.05 mm/s for 1.5 N, and 0.08 ± 0.03 mm/s for 2.0 N. Conclusions: To prevent tissue damage in dental bone surgery, a minimum coolant amount of 30 mL/min is recommended. The working pressure should be chosen with great care because of its significant influence on intraosseous temperature. Doubling of the working pressure from 1.5 to 3.0 N requires a tripling of the coolant (30 to 90 mL/min) to prevent tissue damage. A working pressure above 3.0 N did not result in improved cutting performance. |
| | |
Authors:
|
Falk Birkenfeld; Merlind Erika Becker; Sonke Harder; Ralph Lucius; Matthias Kern |
Related Documents
:
|
7804947 - Errors in assessment of blood pressure: sphygmomanometers and blood pressure cuffs. 23417957 - High-pressure atom transfer radical polymerization of n-butyl acrylate. 16202967 - Basic principles of noninvasive blood pressure measurement in infants. 486727 - Clinical suitability and accuracy of a new combined system for the transcutaneous and i... 11461567 - Orthorhombic intermediate state in the zinc blende to rocksalt transformation path of s... 8551537 - Intrathoracic pressure variations in obese habitual snorers. |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: The International journal of oral & maxillofacial implants Volume: 27 ISSN: 1942-4434 ISO Abbreviation: Int J Oral Maxillofac Implants Publication Date: 2012 Nov |
Date Detail:
|
Created Date: 2012-11-28 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 8611905 Medline TA: Int J Oral Maxillofac Implants Country: United States |
Other Details:
|
Languages: eng Pagination: 1382-8 Citation Subset: D; IM |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Effect of different alloplast materials on the stability of vertically augmented new tissue.
Next Document: Bone regeneration with rabbit bone marrow-derived mesenchymal stem cells and bone graft materials.