Increased intraosseous temperature caused by ultrasonic devices during bone surgery and the influences of working pressure and cooling irrigation.
MedLine Citation:
PMID:  23189287     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Purpose: The purpose of this study was to investigate the increases in intraosseous temperature generated by a modern ultrasonic device for bone surgery (UDBS) and the influences of working pressure and cooling irrigation on this temperature. Materials and Methods: Twenty human mandibular bone specimens (20 x 15 x 5 to 7 mm) were used; three vertical cuts were performed for a duration of 12 seconds per cut. Each bone specimen was machined with a different combination of working pressure (1.5, 2.0, 3.0, 4.0, or 6.0 N) and cooling irrigation (0, 30, 60, or 90 mL/min), and intraosseous temperatures were measured. Harmful temperature development was defined as an increase of more than 10°C for the 75th percentile and/or a maximum increase of more than 15°C. Cutting performance was also measured. Results: Harmless intraosseous temperature development was identified for working pressures of 1.5 N and 2.0 N with cooling irrigations of 30, 60, and 90 mL/min and for 3.0 N at 90 mL/min. The maximum temperature observed was 72°C (6.0 N with 60 mL/min). The mean cutting performance values were 0.21 ± 0.02 mm/s for 6.0 N, 0.21 ± 0.06 mm/s for 3.0 N, 0.20 ± 0.01 mm/s for 4.0 N, 0.11 ± 0.05 mm/s for 1.5 N, and 0.08 ± 0.03 mm/s for 2.0 N. Conclusions: To prevent tissue damage in dental bone surgery, a minimum coolant amount of 30 mL/min is recommended. The working pressure should be chosen with great care because of its significant influence on intraosseous temperature. Doubling of the working pressure from 1.5 to 3.0 N requires a tripling of the coolant (30 to 90 mL/min) to prevent tissue damage. A working pressure above 3.0 N did not result in improved cutting performance.
Authors:
Falk Birkenfeld; Merlind Erika Becker; Sonke Harder; Ralph Lucius; Matthias Kern
Related Documents :
7804947 - Errors in assessment of blood pressure: sphygmomanometers and blood pressure cuffs.
23417957 - High-pressure atom transfer radical polymerization of n-butyl acrylate.
16202967 - Basic principles of noninvasive blood pressure measurement in infants.
486727 - Clinical suitability and accuracy of a new combined system for the transcutaneous and i...
11461567 - Orthorhombic intermediate state in the zinc blende to rocksalt transformation path of s...
8551537 - Intrathoracic pressure variations in obese habitual snorers.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The International journal of oral & maxillofacial implants     Volume:  27     ISSN:  1942-4434     ISO Abbreviation:  Int J Oral Maxillofac Implants     Publication Date:  2012 Nov 
Date Detail:
Created Date:  2012-11-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611905     Medline TA:  Int J Oral Maxillofac Implants     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1382-8     Citation Subset:  D; IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effect of different alloplast materials on the stability of vertically augmented new tissue.
Next Document:  Bone regeneration with rabbit bone marrow-derived mesenchymal stem cells and bone graft materials.