Abstract/OtherAbstract:
Distal embolization protection devices are fast becoming an integral part of percutaneous vein graft interventions. The distal elastomeric balloon of the PercuSurge GuardWire system is supposed to be atraumatic to the vessel wall. We report the inadvertent dilation of a moderate distal stenosis at the site of GuardWire balloon inflation while intervening on a critical proximal saphenous vein graft stenosis. This case illustrates that plaque compression and potential vessel wall trauma might occur during the inflation of the PercuSurge GuardWire distal protection balloon.
Authors:
Naveen Sharma; Vijay G Kalaria
Related Documents :
8028485 - Fatal haemorrhage following intra-aortic balloon counterpulsation: a case report and a ...
681445 - Syringe holder for constant fogarty balloon catheter inflation.
8208695 - Interventional cardiology: state of the art.
22475245 - The effect of tumor necrosis factor-α antagonists on arterial stiffness in rheumatoid ...
8286545 - Three-dimensional reconstruction of the pig sheathed artery.
15221565 - Successful arterial reconstruction with collateral artery bypass for a femoral artery a...
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions     Volume:  59     ISSN:  1522-1946     ISO Abbreviation:  Catheter Cardiovasc Interv     Publication Date:  2003 Jul 
Date Detail:
Created Date:  2003-06-24     Completed Date:  2003-11-19     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  100884139     Medline TA:  Catheter Cardiovasc Interv     Country:  United States    
Other Details:
Languages:  eng     Pagination:  346-9     Citation Subset:  IM    
Copyright Information:
Copyright 2003 Wiley-Liss, Inc.
Affiliation:
Krannert Institute of Cardiology, Clarian Cardiovascular Center, Department of Medicine, Indiana University, Indianapolis, Indiana, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Angioplasty, Balloon / instrumentation*,  methods
Coronary Angiography
Coronary Artery Bypass / adverse effects*,  methods
Coronary Stenosis / radiography,  surgery*
Follow-Up Studies
Graft Occlusion, Vascular / radiography,  therapy*
Humans
Male
Risk Assessment
Saphenous Vein / transplantation*
Severity of Illness Index
Treatment Outcome
Comments/Corrections
Comment In:
Catheter Cardiovasc Interv. 2003 Jul;59(3):350   [PMID:  12822156 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Percutaneous coronary intervention-associated nephropathy foreshadows increased risk of late adverse...
Next Document:  Obstinate thrombosis during percutaneous coronary intervention in a case with heparin-induced thromb...