In vivo assessment of coronary artery angioplasty and stent deployment from balloon pressure-volume data.
MedLine Citation:
PMID:  16462009     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This study assessed the clinical and practical value of angioplasty balloon pressure-volume data, obtained by a computer-controlled balloon inflation device, during standard percutaneous coronary intervention (PCI) procedures. Stent deployment was studied for 57 lesions in 34 patients. Angiographic predilation data were available in 9 patients. Vessel lumen improvement with pre-dilation was determined using the area difference under the pressure-volume curves of two consecutive inflations and compared to the angiographically determined lumen improvement. Stent opening pressure, the inflation volume needed to unfold the stent and the shape of the pressure-volume curve were assessed for differences between stent sizes (diameter, length) and manufacturer types. A Pearson correlation of 0.8 between the pressure-volume area difference and the angiographic lumen improvement was significant (p = 0.01), confirming that pressure-volume curves are useful in assessing lumen improvement after pre-dilation. There was a significant difference in stent opening pressure between stent types but not between different stent sizes (length, diameter). The inflation volume measured during the unfolding process of the stent correlated with the calculated stent lumen when deployed (Pearson correlation: 0.65, p = 0.001). The shape of the pressure-volume curve during stent deployment illustrated differences between different stent sizes (length, diameter) during inflation. Pressure-volume curves obtained from an automatic balloon inflation device have shown their usefulness in providing additional feedback about lumen improvement and the mechanical characteristics and quality of stent deployment.
Authors:
T Olbrich; D O Williams; J C Doig; A Murray
Related Documents :
24756779 - Compliance properties of collagen-coated polyethylene terephthalate vascular prostheses.
25099489 - Hydrogen sulfide treatment reduces blood pressure and oxidative stress in angiotensin i...
23274949 - Characterization of skin dermis microcirculation in flow-mediated dilation using optica...
12578039 - Hemodilution does not alter the aortic-to-femoral arterial pressure difference in dogs.
24309489 - Effect of olmesartan medoxomil on number and survival of circulating endothelial progen...
24296849 - Association between glycemic control and morning blood pressure surge with vascular end...
17772369 - Interior structure of neptune: comparison with uranus.
6684189 - Inhibitory action of prostaglandin e on angiotensin ii-induced enhancement of vasoconst...
10777029 - Transvascular albumin leakage and forearm vasodilatation to acetylcholine in essential ...
Publication Detail:
Type:  Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't     Date:  2006-01-13
Journal Detail:
Title:  Physiological measurement     Volume:  27     ISSN:  0967-3334     ISO Abbreviation:  Physiol Meas     Publication Date:  2006 Mar 
Date Detail:
Created Date:  2006-02-07     Completed Date:  2006-05-17     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  England    
Other Details:
Languages:  eng     Pagination:  213-23     Citation Subset:  IM    
Affiliation:
Medical Physics Department, Freeman Hospital, University of Newcastle upon Tyne, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Transluminal, Percutaneous Coronary / methods*
Blood Pressure
Coronary Artery Disease / diagnosis*,  physiopathology,  therapy*
Coronary Vessels / physiopathology*
Diagnosis, Computer-Assisted / methods
Female
Humans
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity
Treatment Outcome
Vascular Resistance