In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.
MedLine Citation:
PMID:  22898936     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVES: To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. METHODS: Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. RESULTS: Nitinol stents showed significantly better performance than the cobalt chromium stent (P < 0.05) at 1.5 and 3 T. Maximum visible stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". CONCLUSIONS: Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful. KEY POINTS: • Magnetic resonance angiography (MRA) is now widely used instead of digital subtraction angiography • MRA can be considered valid for detection of relevant femoral in-stent restenosis • Applied field strength does not strongly influence lumen assessment of SFA stents • But appropriate choice of field strength might be helpful for some stents.
Authors:
R Syha; D Ketelsen; M Kaempf; S Mangold; S Sixt; T Zeller; F Springer; F Schick; C D Claussen; K Brechtel
Related Documents :
22436646 - Clinical application of an original flexible mk stent-graft for nonruptured thoracic ao...
17511586 - Clinical perspective of hypoxia-mediated pulmonary hypertension.
12946946 - Sildenafil prevents change in rhoa expression induced by chronic hypoxia in rat pulmona...
16936246 - Pulmonary vasodilation by acetazolamide during hypoxia is unrelated to carbonic anhydra...
11250176 - Surgical treatment for popliteal artery entrapment syndrome.
19453826 - Spontaneous internal carotid artery dissection: an uncommon cause of recurrent postpart...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-8-17
Journal Detail:
Title:  European radiology     Volume:  -     ISSN:  1432-1084     ISO Abbreviation:  Eur Radiol     Publication Date:  2012 Aug 
Date Detail:
Created Date:  2012-8-17     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9114774     Medline TA:  Eur Radiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, 72076, Tuebingen, Germany, roland.syha@gmx.net.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clinical application of multi-contrast 7-T MR imaging in multiple sclerosis: increased lesion detect...
Next Document:  Mimicking DNA stretching with the Static Mode method: Shear stress versus transverse pulling stress.