Document Detail


In vitro reproduction of device deformation leading to thrombotic complications and failure of flow diversion.
MedLine Citation:
PMID:  24355146     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Flow diverters (FDs) are increasingly used for complex intracranial aneurysms. As these self-expanding devices are deployed across an aneurysm neck, they can undergo deformations. The potential clinical consequences of FD deformations remain unclear. We describe an immediate thrombotic complication attributed to a stereotypical stenotic deformation of an FD extremity that can occur when landing zones are of insufficient length. This case is supplemented with in vitro studies showing the relationship between i) the length of the landing zones and ii) discrepancies between the diameter of the device and recipient vessel, and the severity of FD stenosis. In vitro, a shorter landing zone was associated with a progressive stenotic deformation of the terminal ends of all FDs studied. This deformation was more pronounced when the diameter of the device was oversized compared to the size of the recipient tube. In our clinical case, the presence of this deformation led to an immediate thrombotic complication, requiring deployment of a second stent to correct the observed stenosis. In addition, treatment failure ultimately led to a fatal rupture, a failure that can be explained by residual flows through a more porous transition zone, another characteristic FD deformation which occurs when they are oversized as compared to the parent vessel, but free to expand at the level of the aneurysm. Proper selection of device diameter and length of the landing zone is important, and may decrease the incidence of deformation-related complications.
Authors:
Laurent Estrade; Alina Makoyeva; Tim E Darsaut; Jimmy Ghostine; Evgueni Kouznetsov; Igor Salazkin; Daniel Roy; Alain Weill; Jean Raymond
Related Documents :
20832066 - Chronic kidney disease is associated with increased carotid artery stiffness without mo...
19424856 - Level of cd14+-endothelial progenitor cells is not associated with coronary artery dise...
15566396 - Arterial stiffness, endothelial function and novel pharmacological approaches.
17331516 - Lipoproteins and protection of the arterial wall against infection: the "response to th...
8983116 - Gigantic patent ductus arteriosus--report of a newborn cadaver dissection and review of...
9933266 - Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurys...
Publication Detail:
Type:  Journal Article     Date:  2013-12-18
Journal Detail:
Title:  Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences     Volume:  19     ISSN:  1591-0199     ISO Abbreviation:  Interv Neuroradiol     Publication Date:  2013 Dec 
Date Detail:
Created Date:  2013-12-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9602695     Medline TA:  Interv Neuroradiol     Country:  Italy    
Other Details:
Languages:  eng     Pagination:  432-7     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Vertebral artery position in the setting of cervical degenerative disease: implications for selectiv...
Next Document:  Susceptibility-weighted imaging in carotido-cavernous fistulas. A case control study.