Document Detail


In vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission.
MedLine Citation:
PMID:  11018459     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Anterior cruciate ligament (ACL) rupture is a major clinical problem leading to instability and degeneration of the knee joint. The problem is compounded by the limited ability of the ACL to heal when ruptured. The existing knowledge regarding the way the ACL ruptures is limited, and this investigation is an attempt to understand the nature of the ruptures using the rabbit as a model. A total of 16 rabbit tibia-ACL-femur complexes were stretched in tension to complete rupture. Four specimens were stretched to failure at a displacement rate of 0.5 mm/min and 12 specimens at 10 mm/min. Acoustic emission (AE) transducers were placed on both the tibia and the femur, and stress wave signals generated during the tensile test were recorded. Fibre fractures produced the highest amplitude signals with a relatively longer rise time. Other failure modes such as matrix failure and debonding produced lower amplitude signals with shorter rise times. We also noted that few events were recorded during the initial period of tensile loading (the elastic phase). The activity then increased significantly after maximum load was reached. The location information provided by the acoustic emission system was consistent with the final site of rupture. We have shown that AE can be used to characterise ligament damage, with fibre pull-outs and fibre fracture producing the highest signal amplitudes.
Authors:
G Azangwe; K Fraser; K J Mathias; A M Siddiqui
Related Documents :
884599 - Dynamic elasticity of human mitral valve chorade tendinease.
18089039 - Load sensing and control of posture and locomotion.
14730649 - Predicting long bone loading from cross-sectional geometry.
8954289 - Use of the force-velocity test to determine the optimal braking force for a sprint exer...
17083089 - Spatial and spectral heterogeneity of time-varying shear stress profiles in the carotid...
10913209 - Role of the forearm interosseous ligament: is it more than just longitudinal load trans...
24483579 - Compression algorithm for discrete light-cone quantization.
7196369 - The diurnal variations of monoamine oxidase activity in discrete nuclei of rat brain.
11117449 - Technical aspects of multifocal erg recording.
Publication Detail:
Type:  In Vitro; Journal Article    
Journal Detail:
Title:  Medical engineering & physics     Volume:  22     ISSN:  1350-4533     ISO Abbreviation:  Med Eng Phys     Publication Date:  2000 May 
Date Detail:
Created Date:  2000-12-11     Completed Date:  2000-12-11     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9422753     Medline TA:  Med Eng Phys     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  279-83     Citation Subset:  IM    
Affiliation:
Department of Bio-Medical Physics and Bio-Engineering, University of Aberdeen, Foresterhill, AB25 2ZD, Aberdeen, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Acoustics
Animals
Anterior Cruciate Ligament / injuries*,  physiopathology
Biomechanics
Biomedical Engineering
Disease Models, Animal
Male
Rabbits
Rupture / physiopathology
Tensile Strength

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Unsteady stenosis flow prediction: a comparative study of non-Newtonian models with operator splitti...
Next Document:  Classification of waist-acceleration signals in a continuous walking record.