In Automated Fluoroscopy Settings Does Shielding Effect Radiation Exposure to Surrounding Unshielded Tissues?
MedLine Citation:
PMID:  22712538     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Abstract Introduction: Automatic brightness control (ABC), a function of modern fluoroscopy machines, adjusts X-ray intensity in real-time to enhance image quality. While shielding reduces radiation exposure to protected areas, it is unknown how much radiation adjacent unshielded areas receive when using ABC settings. Purpose: To assess radiation dosage to shielded and unshielded tissue when using fluoroscopic ABC mode compared to fixed exposure settings. Materials and Methods: In a simulated ureteroscopy, thermoluminescent dosimeters (TLDs) were placed at 3 sites in a female human cadaver, including the right renal hilum, right distal ureter adjacent to the uterus, and directly over the uterus. The cadaver received 60 seconds of radiation exposure using a C-arm fluoroscopy system under ABC and fixed settings (1.38 mAs, 66 kVp) with and without uterine shielding. Radiation dosage absorbed by the TLDs was compared using two-way ANOVA and least-squares confidence intervals. Results: Shielding significantly reduced radiation dose to the uterus by 62% and 82% (p<0.05 for both) in ABC and fixed settings, respectively. However, shielding of the uterus in ABC resulted in an approximately 2-fold increase in radiation dosage to the ureter and ipsilateral kidney (p<0.05 for both) and a decrease in image quality. Using fixed settings, shielding of the uterus did not increase radiation dose to the ipsilateral ureter and kidney. Conclusion: There is a significant increase in radiation dosage to surrounding tissues when shielding is employed with ABC mode during fluoroscopy. Radiation can be reduced and image quality improved by using fixed settings when shielding is indicated.
Authors:
Khanh K Nguyen; Amy E Schlaifer; Kirk M Anderson; Don Arnold; Damien L Smith; Jonathan P Heldt; Joseph E Fargusson; Michael A Fargusson; Hillary J Wagner; Ingrid N Wahjudi; D Duane Baldwin
Related Documents :
3783058 - Human factors design of a video monitor emulator and display (vmed) for visually impair...
10432868 - Correlation of the exposure to a pollutant with a task-related action or workplace: the...
20212718 - Infrared video camera at 10 microm.
10758678 - The observer video-pro: new software for the collection, management, and presentation o...
9060808 - Characterization of collagen by high-frequency ultrasound: evidence for different acous...
7584218 - Magnetic resonance angiography of the body. physical principles and technical challenges.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-6-19
Journal Detail:
Title:  Journal of endourology / Endourological Society     Volume:  -     ISSN:  1557-900X     ISO Abbreviation:  -     Publication Date:  2012 Jun 
Date Detail:
Created Date:  2012-6-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8807503     Medline TA:  J Endourol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Loma Linda Medical Center, Urology, Loma Linda, California, United States; kknguyen@llu.edu.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Intravitreal ranibizumab as an adjunct for ahmed valve surgery in open angle glaucoma: a pilot study...
Next Document:  Beneficial effects of nocturnal hemodialysis in a hemodynamically unstable patient with AL-amyloidos...