Document Detail


Improving functional esophageal surgery with a "smart" bougie: endoflip.
MedLine Citation:
PMID:  21437739     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: An emerging imaging tool, the functional lumen imaging probe (Endoflip; Crospon Ltd, Galway, Ireland), provides a real-time measurement of esophagogastric junction (EGJ) capacity and diameter, which would be of particular interest in functional esophageal surgery such as Heller myotomy and antireflux procedures. This study aimed to demonstrate the intraoperative use of endoflip in the treatment of achalasia and gastroesophageal reflux disease (GERD). METHODS: In the first case, Heller myotomy was performed under endopflip guidance, for persistent dysphagia after failed endoscopic dilatation. In the second case, the endoflip was used to calibrate a Nissen fundoplication. With the patient under general anesthesia, the endoflip catheter was inserted orally and positioned to straddle the EGJ. At each stage of the procedure, the balloon was inflated by liquid filling at 40-30 ml/min. Live diameter data, cross-sectional area (CSA), and balloon pressure were displayed on the system at all times. RESULTS: Before the myotomy, the pressure in the balloon rose to 15 mm Hg at a CSA of 25 mm(2), indicating that the EGJ is rigid and tight. After the myotomy, the pressure rose to 8 mm Hg, and the CSA opened to 34 mm(2), indicating that the EGJ was now very compliant and flaccid. After the Dor fundoplication, the junction became less compliant, but it could open at its narrowest point to 35 mm(2) at a pressure of 20 mm Hg, suggesting that the EGJ was tighter but not as rigid as before. The second part of the video demonstrates that the Endoflip acted as a "smart bougie," evaluating the orientation and position of a properly constructed floppy Nissen. CONCLUSIONS: The endoflip provides a system in which physiology and anatomy are represented dynamically in the same image. This "smart bougie" could be integrated into the surgical routine to improve outcome and to facilitate surgical training and the learning curve in esophageal functional surgery.
Authors:
Silvana Perretta; Bernard Dallemagne; Barry McMahon; Jacopo D'Agostino; Jacques Marescaux
Related Documents :
25424689 - Efficacy and safety evaluation of perindopril-lercanidipine combined therapy in patient...
21239449 - Negative-pressure pulmonary edema presented with concomitant spontaneous pneumomediasti...
25469969 - Field anesthesia machine ventilator oxygen consumption in models of high and low pulmon...
7904909 - Cadmium as hypertensive agent. effect on ion excretion in rats.
1351859 - Increased total vascular capacity in conscious cirrhotic rats.
22528279 - Lack of increase in intracranial pressure after epidural blood patch in spinal cerebros...
9322989 - Circadian blood pressure variability in healthy and complicated pregnancies.
9369279 - Sensitivity of blood pressure and renin activation during sodium restriction.
12881219 - Cytochrome p-450 metabolites but not no, pgi2, and h2o2 contribute to ach-induced hyper...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-3-25
Journal Detail:
Title:  Surgical endoscopy     Volume:  -     ISSN:  1432-2218     ISO Abbreviation:  -     Publication Date:  2011 Mar 
Date Detail:
Created Date:  2011-3-25     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8806653     Medline TA:  Surg Endosc     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
IRCAD-EITS, Department of Digestive and Endocrine Surgery, University of Strasbourg, 1 Place de l'hopital, 67091, Strasbourg Cedex, France, Silvana.perretta@ircad.fr.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The use of curved vs. straight instruments in single port access surgery, on standardized box traine...
Next Document:  Outcome of 141 cases of self-expandable metallic stent placements for malignant and benign colorecta...