Abstract/OtherAbstract:
|
Background Intracranial stents have expanded endovascular therapy to wide neck aneurysms whose dimensions and configurations are not amendable to coil embolization alone. Stents however have not eliminated all problems due to technical factors with their delivery systems. The Neuroform stent system is one of the most widely used for this purpose and has undergone several technical modifications to improve deliverability. Despite improvements in the delivery system there are still reports of failure of stent deployment with the Neuroform 3. Here a simple back table modification is described in which the stent is pushed several centimeters back into the delivery catheter from its manufactured location. This makes the catheter tip more flexible and in our experience improves navigation through vessel curvature and increases deployment rate. Methods Our institution's cerebrovascular database was reviewed retrospectively in compliance with institutional review board approval to identify all Neuroform 3 stents used for assistance with aneurysm embolization since the current stent design became clinically available. Records were reviewed to identify cases of failure of stent placement using the above described technical modification. Results 139 Neuroform 3 stents were placed at our institution for assistance with aneurysm embolization with the technique described above. Only three instances of failure of stent placement related to trackability of the delivery system were identified for a technical failure rate of 2.2%. Conclusions A simple back table modification to the Neuroform 3 delivery system is described which in our single center experience may improve trackability and ultimately successful stent deployment. |
| | |
Authors:
|
Andrew Stephen Ferrell; Kiarash Golshani; Ali Zomorodi; Tony P Smith; Gavin W Britz |
Related Documents
:
|
1217436 - Postoperative changes in bypass vein grafts and collateral arteries after femoropoplite... 21930466 - Bifurcation optimisation stent system (bioss lim) with sirolimus elution: results from ... 3873336 - Spontaneous cerebellar hemorrhage after coronary artery bypass surgery. 16844886 - Minor depression as a cardiac risk factor after coronary artery bypass surgery. 8798126 - Stenting in the carotid artery: initial experience in 110 patients. 8141006 - Screening patients for renal artery stenosis: value of three-dimensional time-of-flight... |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2011-6-28 |
Journal Detail:
|
Title: Journal of neurointerventional surgery Volume: - ISSN: 1759-8486 ISO Abbreviation: - Publication Date: 2011 Jun |
Date Detail:
|
Created Date: 2011-10-12 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 101517079 Medline TA: J Neurointerv Surg Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Affiliation:
|
Department of Radiology, Duke University, Durham, North Carolina, USA. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Efficacy of endovascular surgery for ruptured aneurysms with vasospasm of the parent artery.
Next Document: Developmental venous anomaly coexisting with a true arteriovenous malformation: a rare clinical enti...