Document Detail


Impedance plethysmography in human limbs. Part 1. On electrodes and electrode geometry.
MedLine Citation:
PMID:  1787759     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Electrode design and electrode positioning are important factors in blood flow measurements using impedance plethysmography. Optimal electrode type and accurate positioning will decrease measurement errors and improve the signal-to-noise-ratio. Disk electrodes were found to be superior to tape electrodes because of their better skin-electrode stability and because they prevent limb compression. The distance between current electrodes and potential electrodes should be greater than 2.3 R (disk electrodes) and 1.5 R (tape electrodes) to avoid the influence of the so-called diffusion resistance (R is the radius of the limb at the electrode site).
Authors:
Y Yamamoto; T Yamamoto; P A Oberg
Related Documents :
2424219 - New parameters for evaluation of blood flow in patients with leg ulcers.
7131609 - The effects of thermal injury on rat skeletal muscle microcirculation.
14521299 - Bone marrow perfusion in healthy subjects assessed by scintigraphy after application of...
10029 - The contribution of extraneuronal uptake to the trachea-blood vessel selectivity of bet...
6507969 - Effect of circumferential pneumatic compression devices on digital flow.
18218679 - Alpha-adrenergic inhibition increases collateral circuit conductance in rats following ...
2927159 - The effect of age on cerebral blood flow during hypothermic cardiopulmonary bypass.
17524089 - The safety profile of automated collections: an analysis of more than 1 million collect...
23921899 - Blood-brain barrier dysfunction as a cause and consequence of alzheimer's disease.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Medical & biological engineering & computing     Volume:  29     ISSN:  0140-0118     ISO Abbreviation:  Med Biol Eng Comput     Publication Date:  1991 Jul 
Date Detail:
Created Date:  1992-03-23     Completed Date:  1992-03-23     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7704869     Medline TA:  Med Biol Eng Comput     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  419-24     Citation Subset:  IM    
Affiliation:
Department of Electrical Engineering, Okayama University, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Electrodes
Humans
Leg / blood supply*
Male
Plethysmography, Impedance / instrumentation*
Regional Blood Flow

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Static dynamometer for the measurement of multidirectional forces exerted by the thumb.
Next Document:  Computer simulation of electronic interactions during excitation and repolarisation of myocardial ti...