Document Detail


Impedance cardiography for cuffless and non-invasive measurement of systolic blood pressure.
MedLine Citation:
PMID:  19963978     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
In this study, we have used impedance cardiography to determine blood pressure (BP) cufflessly and non-invasively. We have devised a new parameter, QdZ [the duration measured from the foot of electrocardiogram (ECG) Q wave to the peak of impedance cardiogram (ICG)], for this purpose. Twenty-two subjects performed four minutes of treadmill exercise such that systolic BP (SBP) was increased significantly. We found that SBP was closely correlated with QdZ (R(2)=0.65) demonstrating the potential application of ICG to cuffless and non-invasive BP measurement.
Authors:
M M Wong; E Pickwell-Macpherson; Y T Zhang
Related Documents :
20407368 - Discarding the first of three nurse-auscultatory or oscillometric blood pressure measur...
2967318 - Acromegalic cardiomyopathy. an echocardiographic study.
19694198 - 24-hour blood pressure profiles in children with congenital adrenal hyperplasia on two ...
8942848 - Hypertension in pregnancy: which method of blood pressure measurement is most predictiv...
11597358 - Improved 3-d-echocardiographic endocardial border delineation using the contrast agent ...
21790758 - Ex vivo comparison of three hand sewn end-to-end anastomoses in normal equine jejunum.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference     Volume:  1     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2009  
Date Detail:
Created Date:  2009-12-07     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  800-2     Citation Subset:  IM    
Affiliation:
Joint Research Centre for Biomedical Engineering, Department of Electronic Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Charge Storage: Stability measures in implantable electrodes.
Next Document:  Relation between index finger width and hand width anthropometric measures.