Impact of intermittent apnea on myocardial tissue oxygenation-a study using oxygenation-sensitive cardiovascular magnetic resonance.
MedLine Citation:
PMID:  23301055     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
BACKGROUND: Carbon dioxide (CO(2)) is a recognized vasodilator of myocardial blood vessels that leads to changes in myocardial oxygenation through the recruitment of the coronary flow reserve. Yet, it is unknown whether changes of carbon dioxide induced by breathing maneuvers can be used to modify coronary blood flow and thus myocardial oxygenation. Oxygenation-sensitive cardiovascular magnetic resonance (CMR) using the blood oxygen level-dependent (BOLD) effect allows for non-invasive monitoring of changes of myocardial tissue oxygenation. We hypothesized that mild hypercapnia induced by long breath-holds leads to changes in myocardial oxygenation that can be detected by oxygenation-sensitive CMR.
METHODS AND RESULTS: In nine anaesthetized and ventilated pigs, 60s breath-holds were induced. Left ventricular myocardial and blood pool oxygenation changes, as monitored by oxygenation-sensitive CMR using a T2*-weighted steady-state-free-precession (SSFP) sequence at 1.5T, were compared to changes of blood gas levels obtained immediately prior to and after the breath-hold. Long breath-holds resulted in an increase of paCO(2), accompanied by a decrease of paO(2) and pH. There was a significant decrease of blood pressure, while heart rate did not change. A decrease in the left ventricular blood pool oxygenation was observed, which was similar to drop in SaO(2). Oxygenation in the myocardial tissue however, was maintained throughout the period. Changes in myocardial oxygenation were strongly correlated with the change in paCO(2) during the breath-hold (r = 0.90, p = 0.010).
CONCLUSION: Despite a drop in blood oxygen levels, myocardial oxygenation is maintained throughout long breath-holds and is linearly correlated with the parallel increase of arterial CO(2), a known coronary vasodilator. Breathing maneuvers in combination with oxygenation-sensitive CMR may be useful as a diagnostic test for coronary artery function.
Authors:
Dominik P Guensch; Kady Fischer; Jacqueline A Flewitt; Matthias G Friedrich
Related Documents :
9142155 - Innominate artery occlusive disease: management with central reconstructive techniques.
7722345 - Accuracy and precision of quantitative arteriography in the evaluation of coronary arte...
7897125 - Functional evaluation of internal mammary artery bypass grafts in the early and late po...
22486835 - Application of appropriate use criteria for stress myocardial perfusion imaging at two ...
10072225 - Relation of left ventricular hypertrophy and geometry to asymptomatic cerebrovascular d...
1547195 - Effect of induced hypercholesterolemia in rabbits on functional responses of isolated l...
Publication Detail:
Type:  Journal Article     Date:  2013-01-03
Journal Detail:
Title:  PloS one     Volume:  8     ISSN:  1932-6203     ISO Abbreviation:  PLoS ONE     Publication Date:  2013  
Date Detail:
Created Date:  2013-01-09     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101285081     Medline TA:  PLoS One     Country:  United States    
Other Details:
Languages:  eng     Pagination:  e53282     Citation Subset:  IM    
Affiliation:
Stephenson Cardiovascular MR Centre at the Libin Cardiovascular Institute of Alberta, Departments of Cardiac Sciences and Radiology, University of Calgary, Calgary, Alberta, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Analysis of Virion-Incorporated Host Proteins Required for Herpes Simplex Virus Type 1 Infection thr...
Next Document:  Bioluminescence imaging of DNA synthetic phase of cell cycle in living animals.