Document Detail


Impact of 18F-FDG PET/CT for detecting recurrence of medullary thyroid carcinoma.
MedLine Citation:
PMID:  21946617     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: The aim of this study was to evaluate the value of fluorine-18 (F) fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the detection of recurrent medullary thyroid carcinoma (MTC) in patients with elevated calcitonin levels. METHODS: Thirty-three patients (nine men, 24 women; mean age: 50.3±12 years) who were referred to undergo F-FDG PET/CT for restaging of MTC in patients with high calcitonin levels were included in this study. Five patients also had suspected lymph nodes detected by neck ultrasonography. The results of F-FDG PET/CT and clinical follow-up data were reviewed retrospectively. Histological analysis has been accepted as the gold standard in the confirmation of F-FDG PET/CT results. Patients were followed up for 45.6±4.2 months. RESULTS: There were 14 negative and 19 positive scans for possible recurrence of MTC. In the positive scans, the possible recurrence sites were neck lymph nodes, thyroid bed, mediastinal lymph nodes, and the lung in 14, two, two, and one patient, respectively. Disease recurrence in 13 patients was confirmed histologically by surgical excision or fine-needle aspiration biopsy. In the remaining six patients, recurrence was excluded as it was reactive as a result of pathological examination. However, one patient had a negative scan, underwent neck lymph node excision after F-FDG PET/CT examination, and lymph node recurrence was detected histologically. According to these results, the sensitivity and specificity of PET/CT were calculated as 93 and 68%, respectively. According to the recommended calcitonin level by the American Thyroid Association (calcitonin levels higher than 150 pg/ml), sensitivity was calculated as 90%. Although the mean maximum standardized uptake values of the true-positive and false-positive groups were calculated as 4.72±2.17 and 4.22±1.02, respectively, the difference between the two groups was not statistically significant (P>0.05). CONCLUSION: PET/CT is a sensitive imaging tool in the detection of MTC recurrence, especially in patients with high calcitonin levels, and it gives additional information in one third of all patients on an average by detecting an occult disease or confirming findings of other imaging tools.
Authors:
Elgin Ozkan; Cigdem Soydal; Ozlem N Kucuk; Erkan Ibis; Guner Erbay
Related Documents :
21564557 - The value of non-echo planar (haste) diffusion-weighted mr imaging in the detection, lo...
22112047 - Multimodal imaging and detection approach to 18f-fdg-directed surgery for patients with...
21762907 - Narrow-band imaging versus i-scan for the real-time histological prediction of diminuti...
22186037 - Reversible posterior leukoencephalopathy syndrome accompanying eclampsia: correct diagn...
16520947 - Electron-beam ct as a diagnostic modality in pediatric nephrology and renal transplant ...
22285137 - Bilateral asymmetric tongue classic lipomas.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-9-22
Journal Detail:
Title:  Nuclear medicine communications     Volume:  -     ISSN:  1473-5628     ISO Abbreviation:  -     Publication Date:  2011 Sep 
Date Detail:
Created Date:  2011-9-27     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8201017     Medline TA:  Nucl Med Commun     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Nuclear Medicine, Faculty of Medicine, Ankara University, Ankara, Turkey.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Association of vascular fluoride uptake with vascular calcification and coronary artery disease.
Next Document:  Building PET research collaborations.