Document Detail


Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation.
MedLine Citation:
PMID:  12664124     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4x1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type.
Authors:
David Maintz; Kai-Uwe Juergens; Thomas Wichter; Matthias Grude; Walter Heindel; Roman Fischbach
Related Documents :
8857494 - Stent embolization during intracoronary stenting.
11041484 - The square stent-based large vessel occluder: an experimental pilot study.
1571924 - Percutaneous retrieval of a partially expanded iliac artery stent: case report.
7873864 - Renal artery stent placement: immediate and midterm technical and clinical results.
20971244 - Influence of patient age on procedural selection in mitral valve surgery.
25186174 - Arterial innervation in development and disease.
Publication Detail:
Type:  Comparative Study; In Vitro; Journal Article; Research Support, Non-U.S. Gov't     Date:  2002-09-07
Journal Detail:
Title:  European radiology     Volume:  13     ISSN:  0938-7994     ISO Abbreviation:  Eur Radiol     Publication Date:  2003 Apr 
Date Detail:
Created Date:  2003-03-28     Completed Date:  2003-07-25     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9114774     Medline TA:  Eur Radiol     Country:  Germany    
Other Details:
Languages:  eng     Pagination:  830-5     Citation Subset:  IM    
Affiliation:
Department of Clinical Radiology, University of Münster, Albert-Schweitzer-Strasse 33, 48129 Münster, Germany. maintz@uni-muenster.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Artifacts
Coronary Angiography
Coronary Stenosis / therapy
Equipment Design
Humans
Stents*
Tomography, Spiral Computed*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective va...
Next Document:  Magnetic resonance angiography of the peripheral arteries: current status.