Image quality assurance of soft copy display systems.
MedLine Citation:
PMID:  15988625     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Image quality assurance has traditionally been a high priority in medical imaging departments. Recently, it has often been neglected with the transition from hard copy (film) to soft copy (computer) display systems, which could potentially result in difficulty in reading images or even misdiagnosis. This transition therefore requires careful management such that comparable image quality is achieved at a minimum. It is particularly difficult to maintain appropriate image quality in the clinical settings outside of medical imaging departments because of the volume of display systems and the financial restraints that prohibit the widespread use of dedicated computers and high-quality monitors. In this study, a protocol to test and calibrate display systems was developed and validated by using an inexpensive calibration tool. Using this protocol, monitors were identified in a hospital in which image quality was found to be inadequate for medical image viewing. It was also found that most monitors could achieve a substantial increase in image quality after calibration. For example, the 0 and 5% luminance difference was discernable on 30% of the piloted display systems before calibration, but it was discernable on 100% post calibration. In addition, about 50% of the piloted display systems did not have the maximum luminance (white level) suitably set, and 35% of them did not have the minimum luminance (dark level) suitably set. The results indicate that medical display systems must be carefully selected and strictly monitored, maintained, and calibrated to ensure adequate image quality.
Authors:
Emily Seto; Ali Ursani; Joseph A Cafazzo; Peter G Rossos; Anthony C Easty
Related Documents :
12105695 - Softcopy display quality assurance program at texas children's hospital.
19373375 - From quantum to classical images.
20489095 - Enhancing the radiology learning experience with electronic whiteboard technology.
977275 - Automated rodent respiratory monitor and histogram computer--a preliminary report.
734025 - Body awareness in anorexia nervosa: disturbances in "body image" and "satiety".
24657775 - Anatomical and functional pathways of rhythmogenic inspiratory premotor information flo...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of digital imaging     Volume:  18     ISSN:  0897-1889     ISO Abbreviation:  J Digit Imaging     Publication Date:  2005 Dec 
Date Detail:
Created Date:  2005-11-11     Completed Date:  2006-04-26     Revised Date:  2013-03-14    
Medline Journal Info:
Nlm Unique ID:  9100529     Medline TA:  J Digit Imaging     Country:  United States    
Other Details:
Languages:  eng     Pagination:  280-6     Citation Subset:  IM    
Affiliation:
Department of Medicine, University Health Network, Toronto, Ontario, Canada. Emily.seto@uhn.on.ca
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Calibration
Computer Systems
Computer Terminals*
Data Display*
Humans
Quality Control
Radiographic Image Enhancement / methods*
Radiology Information Systems / standards*
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Rod and cone opsin families differ in spectral tuning domains but not signal transducing domains as ...
Next Document:  General consumer communication tools for improved image management and communication in medicine.