Image guidance shortens the learning curve for K-wire placement - an experimental study.
MedLine Citation:
PMID:  23315784     Owner:  NLM     Status:  Publisher    
BACKGROUND: Computer assisted systems in orthopaedic trauma depend in most cases on fixed reference markers. This work evaluated a reference-free image-based guidance system. Outcome parameters were the number of trials needed to achieve an optimal wire position, the radiation and procedure time, and the learning curve. METHODS: Forty artificial proximal femora covered in polyurethane foam were used and randomized in two groups. Each bone was equipped with a target marker at the fovea capitis femoris. Two surgeons each inserted 20 K-wires, 10 with and 10 without assistance from the guidance system. The aim was to bring the tips of the K-wires as close as possible to the target marker. Both procedures were performed under fluoroscopic control. The new guidance system is based on 2D-C-arm images. Following the procedure the result was determined using computed tomography. RESULTS: The same accuracy (P = 0.34) was achieved with less time (P = 0.0008) and less radiation (P = 0.0002) with the guidance system. However, use of the guidance system did shorten the learning curve of both surgeons, leading to a reduced number of trials (P <0.0001). The learning curve of both surgeons was strongly correlated. From the first trial, the performance of both surgeons while using the guidance system, improved over their performance without the guidance system. CONCLUSIONS: The guidance system helped to achieve an optimal K-wire position with less radiation and less time. The major advantage is the ability of the guidance system to be integrated into the workflow and the short and flat learning curve. Copyright © 2013 John Wiley & Sons, Ltd.
Michael Kraus; Sebastian Weckbach; Almut Jones; Gert Krischak; Florian Gebhard; Hendrik Schöll
Related Documents :
23673234 - Identifying and correcting scan noise and drift in the scanning transmission electron m...
23303694 - Mixed-domain edge-aware image manipulation.
23460484 - Can fluoroscopy-based computer navigation improve entry point selection for intramedull...
23072564 - Graphic imagery is not sufficient for increased attention to cigarette warnings: the ro...
22695334 - Developments in cardiac-specific spect imaging.
3210954 - The center-tapped slotted tube autotransformer resonator: a coil for use with a high-re...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-14
Journal Detail:
Title:  The international journal of medical robotics + computer assisted surgery : MRCAS     Volume:  -     ISSN:  1478-596X     ISO Abbreviation:  Int J Med Robot     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-14     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101250764     Medline TA:  Int J Med Robot     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2013 John Wiley & Sons, Ltd.
Institute of Research in Rehabilitation Medicine, Ulm University, Wuhrstrasse 2/1, 88422, Bad Buchau, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Urinary tract infections in sows in Italy: accuracy of urinalysis and urine culture against histolog...
Next Document:  Syntheses of 2-keto-3-deoxy-D-xylonate and 2-keto-3-deoxy-L-arabinonate as stereochemical probes for...