Document Detail

Image-based modeling of hemodynamics in coronary artery aneurysms caused by Kawasaki disease.
MedLine Citation:
PMID:  22120599     Owner:  NLM     Status:  Publisher    
Kawasaki Disease (KD) is the leading cause of acquired pediatric heart disease. A subset of KD patients develops aneurysms in the coronary arteries, leading to increased risk of thrombosis and myocardial infarction. Currently, there are limited clinical data to guide the management of these patients, and the hemodynamic effects of these aneurysms are unknown. We applied patient-specific modeling to systematically quantify hemodynamics and wall shear stress in coronary arteries with aneurysms caused by KD. We modeled the hemodynamics in the aneurysms using anatomic data obtained by multi-detector computed tomography (CT) in a 10-year-old male subject who suffered KD at age 3 years. The altered hemodynamics were compared to that of a reconstructed normal coronary anatomy using our subject as the model. Computer simulations using a robust finite element framework were used to quantify time-varying shear stresses and particle trajectories in the coronary arteries. We accounted for the cardiac contractility and the microcirculation using physiologic downstream boundary conditions. The presence of aneurysms in the proximal coronary artery leads to flow recirculation, reduced wall shear stress within the aneurysm, and high wall shear stress gradients at the neck of the aneurysm. The wall shear stress in the KD subject (2.95-3.81 dynes/sq cm) was an order of magnitude lower than the normal control model (17.10-27.15 dynes/sq cm). Particle residence times were significantly higher, taking 5 cardiac cycles to fully clear from the aneurysmal regions in the KD subject compared to only 1.3 cardiac cycles from the corresponding regions of the normal model. In this novel quantitative study of hemodynamics in coronary aneurysms caused by KD, we documented markedly abnormal flow patterns that are associated with increased risk of thrombosis. This methodology has the potential to provide further insights into the effects of aneurysms in KD and to help risk stratify patients for appropriate medical and surgical interventions.
Dibyendu Sengupta; Andrew M Kahn; Jane C Burns; Sethuraman Sankaran; Shawn C Shadden; Alison L Marsden
Related Documents :
11097409 - Persistent trigeminal artery variants detected by mr angiography.
10540639 - Ventilation-perfusion lung scintigraphy as a guide for pulmonary angiography in the loc...
2505519 - Cerebral distribution of contrast medium during slow intracarotid infusion.
18307209 - Time-resolved mr angiography for the classification of endoleaks after endovascular ane...
11133569 - Surveillance of peripheral arterial bypass grafts with three-dimensional mr angiography...
2112839 - Intracranial aneurysms: evaluation by mr angiography.
9224519 - Intra-arterial thrombolysis followed by elective surgery for thrombo-embolic popliteal ...
18025989 - Aortic plaque imaging and monitoring atherosclerotic plaque interventions.
21671729 - Ex vivoimaging of injured arteries in rabbits using fluorescence-labelled glycoprotein ...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-11-27
Journal Detail:
Title:  Biomechanics and modeling in mechanobiology     Volume:  -     ISSN:  1617-7940     ISO Abbreviation:  -     Publication Date:  2011 Nov 
Date Detail:
Created Date:  2011-11-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101135325     Medline TA:  Biomech Model Mechanobiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Department of Mechanical and Aerospace Engineering, University of California San Diego (UCSD), San Diego, CA, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Cytotoxicity of dental resin composites: an in vitro evaluation.
Next Document:  Predicting cardiovascular events using three stage Discriminant Function is much more accurate than ...