Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation.
MedLine Citation:
PMID:  10588201     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: This study evaluated the acute physiological gain of adjunctive intravascular ultrasound (IVUS) guided balloon angioplasty and stent implantation. BACKGROUND: Recent studies indicate safe coronary luminal enlargement and "stent-like" long-term outcomes using upsized balloons guided by IVUS. METHODS: After angiographically guided balloon angioplasty in 20 patients with 1-vessel disease and normal left ventricular function, IVUS was performed to determine the size of the adjunctive balloon using the mean of the maximal luminal diameter and the maximal diameter of the external elastic membrane measured in the adjacent proximal and distal reference segments. Serial adenosine-induced hyperemic blood flow velocity measurements were performed using a 0.014" Doppler guide wire to determine the physiological lumen obstruction after standard balloon angioplasty, followed by IVUS-guided balloon angioplasty and stent implantation. RESULTS: Upsized balloon angioplasty (increase balloon size: 0.98 +/- 0.26 mm; balloon:artery ratio 1.35 +/- 0.21) resulted in an additional increase of arterial dimensions: minimal lumen diameter (MLD) 2.18 +/- 0.38 mm to 2.73 +/- 0.51 mm; percent diameter stenosis (%DS) 34 +/- 13% to 19 +/- 22%; IVUS assessed minimal lumen area (MLA) 7.53 +/- 1.55 mm2 to 10.24 +/- 2.22 mm2 (all p < 0.0001). Major dissections (> or = type C) did not occur. Hyperemic blood flow velocity increased from 49.8 +/- 20.1 cm/s to 59.1 +/- 22.9 cm/s (p < 0.05) after IVUS-guided balloon angioplasty. Adjunctive stent implantation resulted in a further increase of MLD to 3.84 +/- 0.51 mm, %DS to -9 +/- 21% and MLA to 13.39 +/- 1.80 mm2 (all p < 0.0001), while hyperemic blood flow velocity remained unchanged (61.2 +/- 24.7 cm/s, p = 0.7). CONCLUSIONS: Upsized IVUS-guided balloon angioplasty increases arterial coronary dimensions and the distal hyperemic blood flow velocity. Adjunctive stent implantation does not yield a further gain in the hyperemic blood flow velocity, indicating the absence of a functional residual lumen obstruction after IVUS-guided balloon angioplasty. This may explain a similar clinical outcome reported after those coronary interventions.
Authors:
R A van Liebergen; J J Piek; K T Koch; R J Peters; R J de Winter; C E Schotborgh; K I Lie
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Journal of the American College of Cardiology     Volume:  34     ISSN:  0735-1097     ISO Abbreviation:  J. Am. Coll. Cardiol.     Publication Date:  1999 Dec 
Date Detail:
Created Date:  1999-12-17     Completed Date:  1999-12-17     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8301365     Medline TA:  J Am Coll Cardiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1899-906     Citation Subset:  AIM; IM    
Affiliation:
Department of Cardiology, Academic Medical Center, University of Amsterdam, The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Angioplasty, Transluminal, Percutaneous Coronary / methods*
Blood Flow Velocity
Blood Vessel Prosthesis Implantation
Coronary Angiography
Coronary Circulation*
Coronary Disease / physiopathology*,  radiography,  therapy,  ultrasonography
Coronary Vessels / physiopathology*,  ultrasonography
Electrocardiography
Female
Heart Catheterization
Humans
Hyperemia / physiopathology*
Male
Middle Aged
Prognosis
Prospective Studies
Safety
Stents*
Ultrasonography, Interventional
Comments/Corrections
Comment In:
J Am Coll Cardiol. 1999 Dec;34(7):1907-9   [PMID:  10588202 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clopidogrel versus ticlopidine after intracoronary stent placement.
Next Document:  Direct coronary stenting without predilation.