Hybrid scatter correction for CT imaging.
MedLine Citation:
PMID:  23038048     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The purpose of this study was to develop and evaluate the hybrid scatter correction algorithm (HSC) for CT imaging. Therefore, two established ways to perform scatter correction, i.e. physical scatter correction based on Monte Carlo simulations and a convolution-based scatter correction algorithm, were combined in order to perform an object-dependent, fast and accurate scatter correction. Based on a reconstructed CT volume, patient-specific scatter intensity is estimated by a coarse Monte Carlo simulation that uses a reduced amount of simulated photons in order to reduce the simulation time. To further speed up the Monte Carlo scatter estimation, scatter intensities are simulated only for a fraction of all projections. In a second step, the high noise estimate of the scatter intensity is used to calibrate the open parameters in a convolution-based algorithm which is then used to correct measured intensities for scatter. Furthermore, the scatter-corrected intensities are used in order to reconstruct a scatter-corrected CT volume data set. To evaluate the scatter reduction potential of HSC, we conducted simulations in a clinical CT geometry and measurements with a flat detector CT system. In the simulation study, HSC-corrected images were compared to scatter-free reference images. For the measurements, no scatter-free reference image was available. Therefore, we used an image corrected with a low-noise Monte Carlo simulation as a reference. The results show that the HSC can significantly reduce scatter artifacts. Compared to the reference images, the error due to scatter artifacts decreased from 100% for uncorrected images to a value below 20% for HSC-corrected images for both the clinical (simulated data) and the flat detector CT geometry (measurement). Compared to a low-noise Monte Carlo simulation, with the HSC the number of photon histories can be reduced by about a factor of 100 per projection without losing correction accuracy. Furthermore, it was sufficient to calibrate the parameters in the convolution model at an angular increment of about 20°. The reduction of the simulated photon histories together with the reduced amount of simulated Monte Carlo scatter projections decreased the total runtime of the scatter correction by about two orders of magnitude for the cases investigated here when using the HSC instead of a low-noise Monte Carlo simulation for scatter correction.
Authors:
Matthias Baer; Marc Kachelrieß
Related Documents :
24036588 - In-line digital holographic microscopy using a consumer scanner.
24439698 - High resolution t2(*)-weighted magnetic resonance imaging at 3 tesla using propeller-epi.
24422898 - Current usage and future trends in gross digital photography in canada.
24674808 - Coordinate geometry method for capturing and evaluating crown preparation geometry.
10427378 - Functional morphology of the locomotor system in the northern smooth-tailed tree shrew ...
22368138 - Potential use of ultrasound speckle tracking for motion management during radiotherapy:...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-05
Journal Detail:
Title:  Physics in medicine and biology     Volume:  57     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-5     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  6849-6867     Citation Subset:  -    
Affiliation:
Institute of Medical Physics (IMP), University of Erlangen-Nürnberg, Henkestr. 91, D-91052 Erlangen, Germany. German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Factors Predicting the Need for Cerebrospinal Fluid Diversion following Posterior Fossa Tumor Surger...
Next Document:  Substituent Effects on Photosensitized Splitting of Thymine Cyclobutane Dimer by an Attached Indole.