Document Detail


Hybrid management of a large atrial septal defect and a patent ductus arteriosus in an infant with chronic lung disease.
MedLine Citation:
PMID:  20814479     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
We report a case wherein a dysmorphic four-month-old infant (weighing 4.5 kgs) with an 8 mm atrial septal defect (ASD), a 1.5 mm patent ductus arteriosus (PDA), a 2 mm mid-muscular ventricular septal defect (VSD) associated with chronic lung disease, and severe pulmonary hypertension, was successfully managed using a hybrid approach, without the use of cardiopulmonary bypass (CPB). Through a median sternotomy, the PDA was ligated and the ASD was closed with a 9 mm Amplatzer septal occluder implanted through peratrial access. The VSD was left untouched. Serial echocardiograms showed complete closure of the ASD and PDA, with progressive normalization of the pulmonary artery (PA) pressures within three months. The child rapidly gained weight and was weaned from sildenafil and oxygen administration. After 12 months, the VSD closed spontaneously and the child remained well, with normal PA pressures. A hybrid approach without the use of CPB should be considered in the management of infants with congenital heart disease, associated with chronic lung disease and pulmonary hypertension.
Authors:
Simone F Pedra; Marcelo Jatene; Carlos Ac Pedra
Related Documents :
17622959 - Renal glomeruli and tubular injury following indomethacin, ibuprofen, and gentamicin ex...
8176569 - Increased incidence of bronchopulmonary dysplasia after antenatal administration of ind...
6858879 - Quantitative angiographic and morphologic aspects of aortic valve atresia.
666429 - Left axillary incision (minithoracotomy) for pda division.
20182439 - Treatment of persistent patent ductus arteriosus in preterm infants: time to accept the...
3632019 - Severe pre-eclampsia and infants of very low birth weight.
12963509 - Analysis of perinatal mortality in a nigerian teaching hospital.
21450729 - Natural 'poor start' does not increase mortality over the lifetime.
8729239 - Bombardier beetle based biosensor.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Annals of pediatric cardiology     Volume:  3     ISSN:  0974-5149     ISO Abbreviation:  Ann Pediatr Cardiol     Publication Date:  2010 Jan 
Date Detail:
Created Date:  2010-09-03     Completed Date:  2011-07-14     Revised Date:  2013-05-29    
Medline Journal Info:
Nlm Unique ID:  101495459     Medline TA:  Ann Pediatr Cardiol     Country:  India    
Other Details:
Languages:  eng     Pagination:  68-73     Citation Subset:  -    
Affiliation:
Hospital do Coração da Associação Sanatório Sírio, São Paulo, Brazil.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Multiple coil closure of isolated aortopulmonary collateral.
Next Document:  Hybrid palliation of interrupted aortic arch in a high-risk neonate.