Much inter- and intra-subject variability in the QT interval in health and disease is accounted for by differences in heart rate, leading to difficulties when determining the effects of disease and drugs on the QT interval. Traditionally, heart rate correction formulae have been used to overcome this problem in man. However, the commonly used Bazett's heart rate correction formulae (QT=QT(C) radical RR interval) does not remove the effect of heart rate; indeed, it overcorrects at high heart rates. Fredericia's formula (QT=QT(C)x(3) radical RR interval) does remove the effects of heart rate; this is the preferable formula, if one is to be used. However, all formulae make assumptions about the nature of the QT-heart rate relationship, assumptions that may not apply to those with disease or on drugs. A more intellectually rigorous approach to QT interval-heart rate correction is to determine the QT-heart relationship for each individual, using data obtained from exercise tests or 24-h Holter tapes. The best mathematical relationship (linear, exponential, etc.) is obtained from analysis of this data, and is used to determine the QT interval at a heart rate of 60 bpm, the QT(60). The QT(60) measure makes no assumptions about the nature of the QT interval-heart rate relationship, removes the dependence of QT interval on heart rate, and maintains genuine biological differences in the QT interval. It should become the standard in QT interval-heart rate correction.
Authors:
Patrick Davey
Related Documents :
58586 - Lidocaine and his bundle extrasystoles. his bundle discharge conducted with functional ...
23666296 - The prognostic value of the cardiopulmonary exercise test in patients with heart failur...
2452426 - Intermittent preexcitation: marked enhancement of anterograde conduction in the atriove...
1704536 - Evaluation of rate-responsive pacemakers by transesophageal holter monitoring of sponta...
3174376 - The use of isometric exercise as a means of evaluating the parasympathetic contribution...
7360956 - Temporal resolution requirements for left ventricular time-activity curves.
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  Journal of pharmacological and toxicological methods     Volume:  48     ISSN:  1056-8719     ISO Abbreviation:  J Pharmacol Toxicol Methods     Publication Date:    2002 Jul-Aug
Date Detail:
Created Date:  2003-05-16     Completed Date:  2003-07-11     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  9206091     Medline TA:  J Pharmacol Toxicol Methods     Country:  United States    
Other Details:
Languages:  eng     Pagination:  3-9     Citation Subset:  IM    
Affiliation:
Northampton General Hospital, Billings Road, Cliftonville, Northampton, NN1 5Bd,UK. patrick.davey@ndm.ox.ac.uk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Calibration
Cardiac Pacing, Artificial
Clinical Trials as Topic
Electrocardiography / standards*
Exercise Test
Heart Rate / drug effects,  physiology*
Humans

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Design and synthesis of a new series of 4-alkylated 3-isoxazolol GABA A antagonists.
Next Document:  A method for QT correction based on beat-to-beat analysis of the QT/RR interval relationship in cons...