Document Detail


A highly accurate and consistent microfluidic viscometer for continuous blood viscosity measurement.
MedLine Citation:
PMID:  20946281     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
A high-precision microfluidic viscometer with a microfluidic channel array composed of 100 indicating channels is demonstrated in this study. The relative viscosity of the sample fluid could be measured by simply counting the number of the indicating channels occupied by the sample and the reference fluids. Using lumped parameter modeling, an analytical solution of the relative viscosity is derived. In order to evaluate the performance of the developed microfluidic viscometer, the viscosity values obtained by the microfluidic viscometer are compared with the ones obtained by a conventional viscometer. In Newtonian fluid (sodium dodecyl sulfate [SDS] solution) tests, the normalized differences in the viscosities measured by two methods are less than 2.5%. In non-Newtonian fluid (whole blood, 45% hematocrit) tests at various shear rates, the viscosities measured by two methods are evaluated by a regression analysis via power law (). The k values for both the microfluidic viscometer and the conventional viscometer are 12.953 and 13.175, respectively; the n values are 0.797 and 0.807, respectively. The normalized differences in two parameters measured by two methods are less than 2%. Thus, it could be concluded that the microfluidic viscometer developed in this study is capable of measuring viscosity of both Newtonian fluid (SDS solution) and non-Newtonian fluid (whole blood) with a relatively high accuracy in a continuous and near real-time fashion. Furthermore, the viscometer could be potentially employed in cardiopulmonary bypass procedures by continuously monitoring viscosity changes due to blood damages and hemodilution.
Authors:
Yang Jun Kang; Sang Youl Yoon; Kyeong-Hwan Lee; Sung Yang
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2010-10-14
Journal Detail:
Title:  Artificial organs     Volume:  34     ISSN:  1525-1594     ISO Abbreviation:  Artif Organs     Publication Date:  2010 Nov 
Date Detail:
Created Date:  2010-11-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  United States    
Other Details:
Languages:  eng     Pagination:  944-9     Citation Subset:  IM    
Copyright Information:
© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Affiliation:
School of Mechatronics, Gwangju Institute of Science and Technology, Buk-gu, Gwangju, Republic of Korea.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Miniaturization of a magnetically levitated axial flow blood pump.
Next Document:  Evaluation of HL-20 roller pump and Rotaflow centrifugal pump on perfusion quality and gaseous micro...