Document Detail


High wall shear stress proximal to myocardial bridging and atherosclerosis: intracoronary ultrasound and pressure measurements.
MedLine Citation:
PMID:  7786662     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Studies have shown that myocardial bridging may prevent coronary atherosclerosis and that the segment proximal to the bridge is often sclerosed. The underlying mechanism is still unknown. METHODS: Intracoronary ultrasound and pressure measurements were performed in a patient with myocardial bridging in the left anterior descending coronary artery. A 3.5 F, 20 MHz probe was used to measure the change in cross sectional area of the lumen during the cardiac cycle. Intracoronary pressure was measured with a Double tip, end mounted pressure transducer system, the catheter having two pressure sensors located at the end of the catheter 3 cm apart. Intracoronary pressure was recorded as the catheter was slowly advanced and pulled back through the left anterior descending coronary artery. RESULTS: Systolic compression of the bridge segment was clearly visualised on ultrasonography and an eccentric plaque with calcium deposit was found in the segment proximal to the bridge. The pressure in the segment proximal to the bridge (160/26 mm Hg) was higher than that of the proximal normal segment (126/68 mm Hg). The pressure distal to the bridge was 68/30 mm Hg. A highly characteristic "sucking effect" was found in the bridge segment. The pressure in the bridge segment was 102/-40 mm Hg. CONCLUSION: The pressure in the segment proximal to the myocardial bridging was higher than aortic pressure. Disturbance of blood flow and high wall stress proximal to myocardial bridging was a main contributor to the development of atherosclerosis in the segment proximal to the bridge.
Authors:
J Ge; R Erbel; G G?rge; M Haude; J Meyer
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  British heart journal     Volume:  73     ISSN:  0007-0769     ISO Abbreviation:  Br Heart J     Publication Date:  1995 May 
Date Detail:
Created Date:  1995-07-27     Completed Date:  1995-07-27     Revised Date:  2010-03-24    
Medline Journal Info:
Nlm Unique ID:  0370634     Medline TA:  Br Heart J     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  462-5     Citation Subset:  AIM; IM    
Affiliation:
Department of Cardiology, University of Essen, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Cardiomyopathies / physiopathology,  ultrasonography*
Coronary Artery Disease / physiopathology,  ultrasonography*
Echocardiography
Electrocardiography
Humans
Male
Pressure
Stress, Mechanical
Transducers, Pressure
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effects of type 1 diabetes mellitus on cardiac function: a study of monozygotic twins.
Next Document:  Do radionuclide and echocardiographic techniques give a universal cut off value for left ventricular...