High-resolution esophageal manometry: addressing thermal drift of the manoscan system.
MedLine Citation:
PMID:  22188326     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: The high resolution esophageal manometry system manufactured by Sierra Scientific Instruments is widely used. The technology is liable to 'thermal drift', a change in measured pressure due to change in temperature. This study aims to characterize 'thermal drift' and minimize its impact.
METHODS: Response of the system to immediate temperature change (20 °C to 37 °C) was tested. Accuracy of pressure measurement over two hours at 37 °C was examined. Six repetitions were performed and median pressure change calculated for each sensor. Sensors were compared using Kruskal-Wallis test. Current correction processes were tested.
KEY RESULTS: There was a biphasic response of the system to body temperature: an immediate change in recorded pressure, 'thermal effect' and an ongoing pressure change with time, 'baseline drift'. Median thermal effect for all 36 sensors was 7 mmHg (IQR 3.8 mmHg). Median baseline drift was 11.1 mmHg (IQR 9.9 mmHg). Baseline drift varied between sensors but for a given sensor was linear. Interpolated thermal compensation, recommended for prolonged studies, corrects data assuming a linear drift of pressures. When pressures were corrected in this way, baseline pressure was almost restored to zero (Median 0.3 mmHg, IQR 0.3). The standard thermal compensation process did not address the error associated with baseline drift.
CONCLUSIONS & INFERENCES: Thermal effect is well compensated in the current operation of the system but baseline drift is not well recognized or addressed. Incorporation of a linear correction into current software would improve accuracy without impact on ease of use.
Authors:
E V Robertson; Y Y Lee; M H Derakhshan; A A Wirz; J R H Whiting; J P Seenan; P Connolly; K E L McColl
Related Documents :
2866476 - Elevated concentrations of glutamate and aspartate in human ventricular cerebrospinal f...
1990906 - Phlebotomy reverses the hemodynamic consequences of thoracic aortic cross-clamping: rel...
606206 - Effects of a new diuretic on cerebrospinal fluid pressure in patients with supratentori...
5118676 - A clinical, pneumoencephalographic and radioisotopic study of normal-pressure communica...
459526 - Specific afterload reduction with parenteral hydralazine following cardiac surgery.
2866476 - Elevated concentrations of glutamate and aspartate in human ventricular cerebrospinal f...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Neurogastroenterology and motility : the official journal of the European Gastrointestinal Motility Society     Volume:  24     ISSN:  1365-2982     ISO Abbreviation:  Neurogastroenterol. Motil.     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2011-12-22     Completed Date:  2012-04-11     Revised Date:  2014-02-20    
Medline Journal Info:
Nlm Unique ID:  9432572     Medline TA:  Neurogastroenterol Motil     Country:  England    
Other Details:
Languages:  eng     Pagination:  61-4, e11     Citation Subset:  IM    
Copyright Information:
© 2011 Blackwell Publishing Ltd.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Body Temperature*
Equipment Design
Esophagus / anatomy & histology,  physiology*
Humans
Manometry / instrumentation*,  methods*,  standards*
Pressure
Reproducibility of Results
Transducers, Pressure
Grant Support
ID/Acronym/Agency:
CZB/4/709//Chief Scientist Office

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Intestinal tissue engineering: current concepts and future vision of regenerative medicine in the gu...
Next Document:  Comparison of the force required to fracture roots vertically after ultrasonic and Masserann removal...