High-pressure cell for neutron reflectometry of supercritical and subcritical fluids at solid interfaces.
MedLine Citation:
PMID:  22559577     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
A new high-pressure cell design for use in neutron reflectometry (NR) for pressures up to 50 MPa and a temperature range of 300-473 K is described. The cell design guides the neutron beam through the working crystal without passing through additional windows or the bulk fluid, which provides for a high neutron transmission, low scattering background, and low beam distortion. The o-ring seal is suitable for a wide range of subcritical and supercritical fluids and ensures high chemical and pressure stability. Wafers with a diameter of 5.08 cm (2 in.) and 5 mm or 10 mm thickness can be used with the cells, depending on the required pressure and momentum transfer range. The fluid volume in the sample cell is very small at about 0.1 ml, which minimizes scattering background and stored energy. The cell design and pressure setup for measurements with supercritical fluids are described. NR data are shown for silicon∕silicon oxide and quartz wafers measured against air and subsequently within the high-pressure cell to demonstrate the neutron characteristics of the high-pressure cell. Neutron reflectivity data for supercritical CO(2) in contact with quartz and Si∕SiO(2) wafers are also shown.
Authors:
Justin R Carmichael; Gernot Rother; James F Browning; John F Ankner; Jose L Banuelos; Lawrence M Anovitz; David J Wesolowski; David R Cole
Related Documents :
14517477 - Blood pressure phenotypes in relation to the beta-adducin c1797t polymorphism in the eu...
22585947 - Cardiorespiratory fitness reduces the risk of incident hypertension associated with a p...
17334527 - Analysis of renin-angiotensin-aldosterone system gene polymorphisms in resistant hypert...
21332327 - Validation of the omron m7 and microlife 3bto-a blood pressure measuring devices in pre...
23472787 - Commercial fishing industry deaths - forensic issues.
8453867 - Breath-by-breath determination of inspiratory occlusion pressure.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Review of scientific instruments     Volume:  83     ISSN:  1089-7623     ISO Abbreviation:  Rev Sci Instrum     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-05-07     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0405571     Medline TA:  Rev Sci Instrum     Country:  United States    
Other Details:
Languages:  eng     Pagination:  045108     Citation Subset:  IM    
Affiliation:
Neutron Scattering Science Division, Oak Ridge National Laboratory, Tennessee 37831, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Implementation of high-resolution time-to-digital converter in 8-bit microcontrollers.
Next Document:  A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency dom...