Document Detail


High inter-specimen variability of baseline data for the tibio-talar contact area.
MedLine Citation:
PMID:  19056155     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: The tibio-talar contact area has been widely investigated to monitor biomechanical changes due to articular incongruities or an altered loading. This study aims to investigate for the first time in a systematic way the extent of the inter-specimen variability of the tibio-talar contact area, and its repercussions when analyzing data concerning this parameter. METHODS: Ten specimens were loaded to record the tibio-talar contact characteristics by use of pressure sensitive film. The size of the talar dome area, the size of the (normalized) tibio-talar contact area, the position of the tibio-talar contact area, and the shape of the latter were determined and analyzed. Inter-specimen variability was expressed as the coefficient of variation and was calculated for the datasets of previous studies as well. FINDINGS: The size of the tibio-talar contact area showed a very high inter-specimen variability, as is the case in previous studies. This high variability persisted when a normalized tibio-talar contact area was calculated. The shape of the tibio-talar contact area showed some basic characteristics, but a high variation in details could be observed. INTERPRETATION: Every specimen can be considered to have its own "ankle print". By this variability, articular incongruities are expected to have a different effect on local biomechanical characteristics in every single individual. Therefore, every single case has to be evaluated and reported for significant changes. In case of modeling, this also underscores the need to use subject specific models fed by sets of parameters derived from a series of single specimens.
Authors:
Giovanni A Matricali; Ward Bartels; Luc Labey; Greta Ph E Dereymaeker; Frank P Luyten; Jos Vander Sloten
Related Documents :
21036655 - Evaluation of the generality and accuracy of a new mesh morphing procedure for the huma...
18643135 - Intermittency of principal stress directions within arctic sea ice.
20561895 - Nonlinear associations between chronic stress and cardiovascular reactivity and recovery.
24497645 - Identification of the intracellular gate for a member of the equilibrative nucleoside t...
23087495 - Estimation of the disease-specific diagnostic marker distribution under verification bias.
21931175 - Spherical dcb-spline surfaces with hierarchical and adaptive knot insertion.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2008-12-03
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  24     ISSN:  1879-1271     ISO Abbreviation:  Clin Biomech (Bristol, Avon)     Publication Date:  2009 Jan 
Date Detail:
Created Date:  2008-12-16     Completed Date:  2009-02-27     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  England    
Other Details:
Languages:  eng     Pagination:  117-20     Citation Subset:  IM    
Affiliation:
Department of Musculoskeletal Sciences, Katholieke Universiteit Leuven, Leuven, Belgium. giovanni.matricali@uzleuven.be
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Ankle Joint / anatomy & histology*
Bias (Epidemiology)
Biomechanics
Humans
Pressure
Reference Values
Talus / anatomy & histology*
Tibia / anatomy & histology*
Weights and Measures*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Enhancing problem solving and nursing diagnosis in year III Bachelor of Nursing students.
Next Document:  Major reduction in AIDS-mortality inequalities after HAART: the importance of absolute differences i...