Document Detail


Hemostatic control of coronary arteries with poloxamer 407 reverse-thermal polymer during off-pump coronary artery bypass surgery in a pig model.
MedLine Citation:
PMID:  22436876     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
OBJECTIVE: : To evaluate a new material, poloxamer 407 reverse-thermal polymer, which may be of value in controlling bleeding during off-pump coronary anastomoses.
METHODS: : Poloxamer 407 reverse-thermal polymer is a clear, nontoxic compound that is a viscous liquid at room temperature but instantly changes to a firm, water-soluble gel when warmed to body temperature. Six pigs underwent off-pump coronary artery bypass with the left internal mammary artery to the left anterior descending coronary artery. Blood loss from the arteriotomy was measured over a 15-minute period before and after injection of 500 μL intracoronary polymer. After completion of the anastomosis, 10 mL of cold saline was poured along the left anterior descending artery to facilitate dissolution of the polymer. The heart was allowed to beat 2 additional hours with blood flowing through the left internal mammary to left anterior descending graft, after which a completion angiogram was obtained to evaluate graft patency and to look for gross angiographic evidence of coronary branch occlusion or intraluminal filling defects. The animals were then humanely euthanized, and myocardium from the area subtended by the left anterior descending was harvested for histologic evaluation.
RESULTS: : All animals successfully underwent the surgical procedure and survived until study termination without any complications. The amount of bleeding from coronary arteriotomy was significantly higher before intracoronary injection of the polymer (5.25 ± 1.65 mL/min versus 0.54 ± 0.53 mL/min, P = 0.0004). Angiography demonstrated that the graft was patent, and there was no evidence of intraluminal foreign bodies. Myocardial samples from the subtended bed showed no evidence of intraarterial polymer or myonecrosis.
CONCLUSIONS: : Poloxamer 407 reverse-thermal polymer may be a valuable tool in performing coronary anastomoses off-pump. Completion angiograms showed total dissolution of the material with no residual intraarterial polymer visible on tissue samples.
Authors:
William E Cohn; Egemen Tuzun; Ryan Simonak; Fred Baimbridge
Related Documents :
22030356 - A novel two-stage surgical approach for the treatment of symptomatic supra-aortic arter...
10779846 - Morning glory disk anomaly, choroidal coloboma, and congenital constrictive malformatio...
22618986 - Aortic valve replacement for a patient with anomalous left coronary artery from the rig...
6717796 - Clinico-radiological spectrum of giant supraclinoid internal carotid artery aneurysms. ...
21236506 - Underestimation of aortic valve area in calcified aortic valve disease: effects of left...
15121546 - Anatomical variations of the cystic artery.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Innovations (Philadelphia, Pa.)     Volume:  2     ISSN:  1556-9845     ISO Abbreviation:  Innovations (Phila)     Publication Date:  2007 Jan 
Date Detail:
Created Date:  2012-03-22     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101257528     Medline TA:  Innovations (Phila)     Country:  United States    
Other Details:
Languages:  eng     Pagination:  36-9     Citation Subset:  -    
Affiliation:
From *Cardiovascular Surgical Research Laboratories, Texas Heart Institute at St. Luke's Episcopal Hospital, Houston, Texas; and the †Division of Cardiothoracic Surgery, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, Texas.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Use of peripheral ultrafiltration in the postoperative cardiac surgery patient.
Next Document:  Minimally invasive surgical cardiac resynchronization therapy: an intermediate-term follow-up study.