Hemoptysis caused by saphenous vein graft perforation during percutaneous coronary intervention.
MedLine Citation:
PMID:  23293186     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Percutaneous coronary intervention carries the risk of coronary artery perforation, which may lead to serious adverse effects such as cardiac tamponade, myocardial infarction, and even death. We describe a patient who developed hemoptysis immediately after saphenous vein graft rupture, which is a rare complication during coronary intervention. Stenting using a covered stent, along with simultaneous administration of protamine, helped seal the vein graft perforation and stop the hemoptysis.
Authors:
Dong-Yi Chen; Chun-Chi Chen; I-Chang Hsieh
Related Documents :
17323596 - Isosorbide dinitrate-hydralazine combination therapy in african americans with heart fa...
20216156 - Pathophysiology of right ventricular failure in pulmonary hypertension.
25478486 - Partially unroofed coronary sinus with intact atrial septum in an elderly patient.
11960586 - Is heart failure with preserved systolic function an overlooked enigma?
11139786 - Floppy mitral valve, mitral valve prolapse, and mitral valvular regurgitation.
17157396 - Circulating angiogenic cytokines and stem cells in patients with severe chronic ischemi...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Journal of invasive cardiology     Volume:  25     ISSN:  1557-2501     ISO Abbreviation:  J Invasive Cardiol     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-01-07     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8917477     Medline TA:  J Invasive Cardiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  E8-E10     Citation Subset:  IM    
Affiliation:
Second Section of Cardiology, Department of Medicine, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan, Taiwan. hsiehic@ms28.hinet.net.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Left main coronary stent positioning using rapid transcoronary pacing.
Next Document:  Use of acetylcysteine for non-acetaminophen-induced acute liver failure.