Document Detail


Hemodynamic effects of spiral ePTFE prosthesis compared with standard arteriovenous graft in a carotid to jugular vein porcine model.
MedLine Citation:
PMID:  21140362     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Introduction: The primary patency rate of arteriovenous (AV) grafts is limited by distal venous anastomosis stenosis or occlusion due to intimal hyperplasia associated with distal graft turbulence. The normal blood flow in native arteries is spiral laminar flow. Standard vascular grafts do not produce spiral laminar flow at the distal anastomosis. Vascular grafts which induce a spiral laminar flow distally result in lower turbulence, particularly near the vessel wall. This initial study compares the hemodynamic effects of a spiral flow-inducing graft and a standard graft in a new AV carotid to jugular vein crossover graft porcine model. Methods: Four spiral flow grafts and 4 control grafts were implanted from the carotid artery to the contralateral jugular vein in 4 pigs. Two animals were terminated after 48 hours and 2 at 14 days. Graft patency was assessed by selective catheter digital angiography, and the flow pattern was assessed by intraoperative flow probe and color Doppler ultrasound (CDU) measurements. The spiral grafts were also assessed at enhanced flow rates using an external roller pump to simulate increased flow rates that may occur during dialysis using a standard dialysis needle cannulation. The method increased the flow rate through the graft by 660 ml/min. The graft distal anastomotic appearances were evaluated by explant histopathology. Results: All grafts were patent at explantation with no complications. All anastomoses were found to be wide open and showed no significant angiographic stenosis at the distal anastomosis in both spiral and control grafts. CDU examinations showed a spiral flow pattern in the spiral graft and double helix pattern in the control graft. No gross histopathological effects were seen in either spiral or control grafts. Conclusion: This porcine model is robust and allows hemodynamic flow assessment up to 14 days postimplantation. The spiral flow-inducing grafts produced and maintained spiral flow at baseline and enhanced flow rates during dialysis needle cannulation, whereas control grafts did not produce spiral flow through the distal anastomosis. There was no deleterious effect of the spiral flow-inducing graft on macroscopic and histological examination. The reducing effect of spiral flow on intima hyperplasia formation will be the subject of further study using the same AV graft model at a longer period of implantation.
Authors:
Ommid Kh Jahrome; Imo Hoefer; Graeme J Houston; Peter A Stonebridge; Peter J Blankestijn; Frans L Moll; Gert J de Borst
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The journal of vascular access     Volume:  12     ISSN:  1724-6032     ISO Abbreviation:  J Vasc Access     Publication Date:    2011 Jul-Sep
Date Detail:
Created Date:  2011-09-22     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100940729     Medline TA:  J Vasc Access     Country:  Italy    
Other Details:
Languages:  eng     Pagination:  224-30     Citation Subset:  IM    
Affiliation:
Department of Vascular Surgery, University Medical Center, Utrecht - The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effectiveness of sutureless percutaneous placement of cuffed tunneled hemodialysis catheters applyin...
Next Document:  Nd:YAG laser capsulotomy: a survey of UK practice and recommendations.