Hemodynamic assessment of carbomedics bileaflet heart valves by ultrasound: studies in the aortic and mitral positions.
MedLine Citation:
PMID:  8795169     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The bileaflet mechanical heart valve has become a popular prosthesis for implantation in both the aortic and mitral positions and a recent design by Carbomedics has received widespread use. Noninvasive assessment of these valves by Doppler ultrasound is important in characterizing their normal performance and in assessing the course of dysfunction. This study addressed the hypothesis that Doppler predicted pressure drops will correlate with catheter pressure drops within a valve size and position. A subhypothesis is that the pressure drops agree, and we expect this subhypothesis to fail due to pressure recovery effects. In a well-controlled in vitro model it was shown that the combined effects of pressure recovery and neglecting proximal velocities resulted in overestimation of catheter pressure drops for Carbomedics bileaflet valves. Inclusion of the proximal velocity reduced overestimation of peak pressure drops for aortic and mitral valves to clinically acceptable levels, and removed overestimation of mean pressure drops. Without correction for proximal velocity, overestimation of mitral pressure drops was reduced to 3.32% when means were calculated, but mean aortic pressure drops still overestimated the catheter standard significantly. It is concluded that proximal velocities should be included in Bernoulli analysis of Carbomedics heart valves. If the proximal velocity is not available, mitral valves may be best assessed using mean pressure drops, while aortic valve Doppler data, peak or mean, should be interpreted with caution.
Authors:
E G Cape; H W Sung; A P Yoganathan
Related Documents :
12808669 - Abnormal cardiac function in fetuses with increased nuchal translucency.
14640109 - Noninvasive assessment of mitral inertness [correction of inertance]: clinical results ...
7621479 - Overdrainage and shunt technology. a critical comparison of programmable, hydrostatic a...
23540549 - Invasive assessment of doubtful aortic stenosis by measuring simultaneous transaortic g...
2353649 - Validation and applications of mitral prosthetic valvular areas calculated by doppler e...
7460479 - Plethysmographic comparison of sublingual and intramuscular ergotamine.
17159089 - Population-based sample reveals gene-gender interactions in blood pressure in white ame...
2670349 - Blood pressure response to norepinephrine and angiotensin ii in the offspring of parath...
7920979 - Use of a mean systemic filling pressure analogue during the closed-loop control of flui...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Ultrasound in medicine & biology     Volume:  22     ISSN:  0301-5629     ISO Abbreviation:  Ultrasound Med Biol     Publication Date:  1996  
Date Detail:
Created Date:  1996-11-14     Completed Date:  1996-11-14     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  0410553     Medline TA:  Ultrasound Med Biol     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  421-30     Citation Subset:  IM    
Affiliation:
Cardiac Dynamics Laboratory, Children's Hospital of Pittsburgh, University of Pittsburgh, PA, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aortic Valve / physiology*,  ultrasonography
Blood Pressure
Heart Valve Prosthesis*
Hemodynamics / physiology
Humans
Mitral Valve / physiology*,  ultrasonography
Models, Anatomic
Regression Analysis
Ultrasonography, Doppler / methods*