Document Detail


Head and neck squamous cell carcinoma: value of diffusion-weighted MR imaging for nodal staging.
MedLine Citation:
PMID:  19251938     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To evaluate diffusion-weighted (DW) magnetic resonance (MR) imaging, as compared with turbo spin-echo MR imaging, for the detection of nodal metastases in head and neck squamous cell carcinoma (HNSCC). MATERIALS AND METHODS: The study was approved by the ethics committee, and patients gave written informed consent. Before undergoing surgery, 33 consecutive patients underwent 1.5-T MR imaging, including DW imaging performed with a wide range of b values (0-1000 sec/mm(2)). The apparent diffusion coefficients (ADCs) of lymph nodes 4 mm or greater in short-axis diameter depicted on images obtained with b values of 0 and 1000 sec/mm(2) were calculated. After topographic correlation, the lymph nodes were evaluated microscopically with prekeratin immunostaining. The optimal ADC thresholds for discriminating between metastatic and benign lymph nodes were determined. The sensitivity, specificity, and accuracy of DW imaging were calculated separately-on per-lymph-node and per-neck-level bases-for all lymph nodes and for supracentimeter and subcentimeter lymph nodes and were compared with corresponding turbo spin-echo MR imaging values. RESULTS: Correlation of histopathologic and radiologic findings was possible for 301 lymph nodes. The ADC derived from the signal intensity averaged across images obtained with b values of 0 and 1000 sec/mm(2) (ADC(b0-1000)) was 1.19 x 10(-3) mm(2)/sec +/- 0.22 (standard deviation) for benign lymph nodes and 0.85 x 10(-3) mm(2)/sec +/- 0.27 for malignant lymph nodes (P < .0001). With an optimal ADC(b0-1000) threshold of 0.94 x 10(-3) mm(2)/sec, 84% sensitivity, 94% specificity, and 91% accuracy for differentiation of malignant versus benign status of each lymph node and 94% sensitivity, 97% specificity, and 97% accuracy for differentiation at each neck level were achieved. Compared with turbo spin-echo imaging, DW imaging had higher sensitivity (76% vs 7%) but slightly lower specificity (94.0% vs 99.5%) for detection of subcentimeter nodal metastases. CONCLUSION: DW imaging performed with ADC(b0-1000) values had higher accuracy than turbo spin-echo MR imaging in nodal staging, providing added value in the detection of subcentimeter nodal metastases.
Authors:
Vincent Vandecaveye; Frederik De Keyzer; Vincent Vander Poorten; Piet Dirix; Eric Verbeken; Sandra Nuyts; Robert Hermans
Related Documents :
6682248 - Implications of lymphoscintigraphy in oncologic practice: principles and differences vi...
8228088 - Magnetic resonance imaging evaluation of the local extent of colorectal mass lesions.
17535778 - Magnetic resonance imaging of the cervix.
2015918 - The value of magnetic resonance imaging in patients with carcinoma of the cervix (a pil...
17482948 - Symptomatic calcification of subureteral collagen ten years after injection.
12679628 - Detection of small hypervascular hepatocellular carcinomas in cirrhotic patients: compa...
Publication Detail:
Type:  Evaluation Studies; Journal Article; Research Support, Non-U.S. Gov't     Date:  2009-02-27
Journal Detail:
Title:  Radiology     Volume:  251     ISSN:  1527-1315     ISO Abbreviation:  Radiology     Publication Date:  2009 Apr 
Date Detail:
Created Date:  2009-03-31     Completed Date:  2009-04-22     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401260     Medline TA:  Radiology     Country:  United States    
Other Details:
Languages:  eng     Pagination:  134-46     Citation Subset:  AIM; IM    
Affiliation:
Department of Radiology, University Hospitals Leuven, Leuven, Belgium.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Carcinoma, Squamous Cell / pathology*,  secondary*
Diffusion Magnetic Resonance Imaging / methods*
Female
Head and Neck Neoplasms / pathology*
Humans
Lymph Nodes / pathology*
Lymphatic Metastasis
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radiofrequency ablation induces antigen-presenting cell infiltration and amplification of weak tumor...
Next Document:  Urinary calculi: radiation dose reduction of 50% and 75% at CT--effect on sensitivity.