BACKGROUND: Gastrostomy tube (g-tube) dislodgement is a common problem in special needs children. There are no studies on the frequency of complications after g-tube replacement for children in a pediatric emergency department (ED). OBJECTIVES: The objective of this study is to determine the frequency of misplacement and subsequent complications for children undergoing g-tube replacement in a pediatric ED and the impact of contrast-enhanced confirmatory imaging on ED length of stay (LOS). METHODS: This was a retrospective review of children presenting to a pediatric ED over 16 months. Subjects were included if they underwent g-tube replacement in the ED. Records were reviewed for historical and procedural data including patient age, g-tube age, ED LOS, documented difficulties replacing the tube, performance of confirmatory imaging (contrast-enhanced radiograph), and complications identified within 72 hours of ED visit. RESULTS: A total of 237 children met inclusion criteria. Three (1.2%) had evidence of g-tube misplacement, all of whom underwent confirmatory imaging. One complication from misplacement was identified (gastric outlet obstruction from overfilled balloon). Tract disruption was not identified for any subject. Eighty-four subjects (35%) had confirmatory imaging performed after replacement. Mean ED LOS in the imaged group was 265 vs 142 minutes for the nonimaged group (P < .001). No subjects with documentation of clinical confirmation had subsequent evidence of misplacement. CONCLUSIONS: For children undergoing g-tube replacement in a pediatric ED, misplacement and associated complications were rare. Confirmatory imaging was associated with a considerably longer LOS. In the presence of clinical confirmation, confirmatory imaging may be judiciously used.
Authors:
Cory D Showalter; Benjamin Kerrey; Stephanie Spellman-Kennebeck; Nathan Timm
Related Documents :
22547266 - Mammographic system performance using an image reading qualification method.
24695846 - Numerical simulation of x-ray luminescence optical tomography for small-animal imaging.
10734576 - Binding assays in heterogeneous media using a flow injection system with an expanded mi...
1666646 - Electron microscopic observation of recombinant escherichia coli cells overproducing hu...
2726206 - Image analysis of radiolucencies in approximal enamel: a comparison of xeroradiographic...
22987786 - Effects of brief mindfulness instructions on reactions to body image stimuli among fema...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-2-3
Journal Detail:
Title:  The American journal of emergency medicine     Volume:  -     ISSN:  1532-8171     ISO Abbreviation:  -     Publication Date:  2012 Feb 
Date Detail:
Created Date:  2012-2-6     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8309942     Medline TA:  Am J Emerg Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2011. Published by Elsevier Inc.
Affiliation:
Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH 45229, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Accuracy of emergency physicians using ultrasound measurement of crown-rump length to estimate gesta...
Next Document:  Acute aortic dissection in the ED: risk factors and predictors for missed diagnosis.