Document Detail


Fuzzy logic assisted control of inspired oxygen in ventilated newborn infants.
MedLine Citation:
PMID:  7950026     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The control of oxygen delivery to mechanically ventilated newborn infants is a time intensive process that must balance adequate tissue oxygenation against possible toxic effects of oxygen exposure. Investigation in computer assisted control of mechanical ventilation is increasing, although very few studies involve newborn infants. We have implemented a fuzzy controller for the adjustment of inspired oxygen concentration (FIO2) in ventilated newborns. The controller utilizes rules produced by neonatologists, and operates in real-time. A clinical trial of this controller is currently taking place in the neonatal intensive care unit (NICU) of Children's Hospital, Boston, MA.
Authors:
Y Sun; I Kohane; A R Stark
Related Documents :
2893136 - Percutaneous oxygen delivery to the preterm infant.
1396256 - The use of high-frequency oscillatory ventilation (hfov) and extracorporeal membrane ox...
15266466 - Air versus oxygen for resuscitation of infants at birth.
8725696 - The use of a second course of extracorporeal membrane oxygenation in neonatal patients.
3501226 - Type of milk feeding and nutrient intake during infancy. the leiden pre-school children...
25020996 - Pld.56 empirical treatment of early neonatal infection and the postnatal service.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Proceedings / the ... Annual Symposium on Computer Application [sic] in Medical Care. Symposium on Computer Applications in Medical Care     Volume:  -     ISSN:  0195-4210     ISO Abbreviation:  Proc Annu Symp Comput Appl Med Care     Publication Date:  1994  
Date Detail:
Created Date:  1994-12-23     Completed Date:  1994-12-23     Revised Date:  2009-11-18    
Medline Journal Info:
Nlm Unique ID:  8113685     Medline TA:  Proc Annu Symp Comput Appl Med Care     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  757-61     Citation Subset:  IM    
Affiliation:
Children's Hospital, Harvard Medical School, Boston, MA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Computer Systems*
Fuzzy Logic*
Humans
Infant, Newborn* / blood
Microcomputers
Monitoring, Physiologic / instrumentation*
Oximetry / instrumentation
Oxygen / blood
Respiration, Artificial / instrumentation*
Therapy, Computer-Assisted*
Chemical
Reg. No./Substance:
7782-44-7/Oxygen
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Advanced clinical monitoring: considerations for real-time hemodynamic diagnostics.
Next Document:  Performance evaluation of a distance learning program.