Document Detail


Frequency tuning of bone-conducted tone burst-evoked myogenic potentials recorded from extraocular muscles (BOVEMP) in normal human subjects.
MedLine Citation:
PMID:  21108434     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: In this study, we characterized the frequency tuning of bone-conducted sound-evoked myogenic potentials recorded from extraocular muscles (BOVEMP) in normal human subjects.
STUDY DESIGN: Experimental design.
METHODS: In a sample of nine subjects, acoustic tone bursts (57 dB nHL, 8 ms plateau, 1 ms rise/fall, alternating polarity) with frequencies from 250 Hz to 2,000 Hz were delivered by a bone oscillator (Radioear B-71) placed on the left mastoid processes. Subjects were required to sit upright and maintain a straight gaze. The BOVEMPs were recorded from surface electrodes placed at four locations around the right eye (superior, inferior, nasal, and temporal) and referenced to an electrode placed at the nape of the neck over cervical vertebrate C7. Signals from electrodes were amplified (10,000 gain) and sampled at 10 kHz and were averaged over 500 repetitions.
RESULTS: Short latency biphasic potential were present at each of the four recording sites around the eye. The average latency of the first peak (negative) and the second peak (positive) was 15.7 ± 0.3 ms and 23.3 ± 0.5 ms, respectively. The tuning curve of the BOVEMP was similar at each recording site with largest N1 amplitude following stimulation at 383 Hz (± 17 Hz) and largest P1 amplitude following stimulation at 440 Hz (± 22 Hz).
CONCLUSIONS: Since the frequency tuning for the bone-conducted sound-evoked OVEMP (BOVEMP) was different from that of the air-conducted sound-evoked OVEMP (AOVEMP), we hypothesize that the BOVEMP and AOVEMP are generated by activation of different vestibular end organs.
Authors:
Kimberly Donnellan; Wei Wei; Ben Jeffcoat; William Mustain; Youguo Xu; Thomas Eby; Wu Zhou Phd
Related Documents :
23038344 - Polarization dependent light extraction of a gan light emitting diode using dark field ...
3392974 - Frequency response of the arterial wall.
15261864 - Somatosensory evoked high-frequency oscillations in migraine patients.
22466074 - Reverse transmission along the ossicular chain in gerbil.
16558384 - Chronic brachial plexopathies and upper extremity proprioception and strength.
20661644 - Spad chlorophyll meter reading can be pronouncedly affected by chloroplast movement.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  The Laryngoscope     Volume:  120     ISSN:  1531-4995     ISO Abbreviation:  Laryngoscope     Publication Date:  2010 Dec 
Date Detail:
Created Date:  2010-11-25     Completed Date:  2011-01-20     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8607378     Medline TA:  Laryngoscope     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2555-60     Citation Subset:  IM    
Affiliation:
Department of Otolaryngology and Communicative Sciences, University of Mississippi Medical Center, Jackson, Mississippi, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Acoustic Stimulation / methods*
Adult
Auditory Threshold / physiology*
Bone Conduction / physiology*
Electrodes
Evoked Potentials, Auditory / physiology*
Face
Female
Humans
Male
Muscle, Skeletal / physiology*
Neck
Reference Values