Document Detail


Four-detector row computed tomographic angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease: influence of contrast medium concentration.
MedLine Citation:
PMID:  18830096     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To prospectively compare the diagnostic accuracy and quality of vascular enhancement of 2 contrast agents with different iodine concentrations in 4-detector row computed tomographic angiography of abdominal aorta and lower-extremity arteries. MATERIALS AND METHODS: Forty consecutive patients with peripheral arterial occlusive disease referred for conventional angiography (digital subtraction angiography [DSA]) of the lower extremity were prospectively enrolled in the study and underwent multidetector row computed tomographic angiography (CTA) receiving either 90 mL of iomeprol 400 (Iomeron 400, group A; Bracco Imaging S.p.A., Milan, Italy) or 120 mL of iomeprol 300 (Iomeron 300, group B; Bracco Imaging). Resultant images, both axial, maximum intensity projection, multiplanar reformatted, and volume-rendered 3-dimensional images, were independently evaluated by 2 clinically competent and experienced blinded radiologists for the presence of stenotic and occluded arterial segments using DSA as the standard of reference. Computed tomographic images were also evaluated quantitatively for maximum arterial and venous enhancement, and qualitatively for vascular opacification, venous overlap, and diagnostic efficacy. Quantitative and qualitative results of the 2 study agent groups were statistically compared. Both contrast media were evaluated for safety and tolerability. RESULTS: From 760 segments, 722 arterial segments were effectively evaluated in the comparative analysis of CTA and DSA. In the evaluation of significant stenoses (>70%) and occluded segments, multidetector row CTA obtained a sensitivity, specificity, and accuracy of 97.1%, 96%, and 96.3%, and 98.9%, 100%, and 99%, respectively. Iomeprol 400 demonstrated an increased arterial enhancement in aortoiliac and femoral districts in comparison to iomeprol 300 (mean increase in opacification, 37.3 Hounsfield units) and a significant better qualitative assessment in the aortoiliac segments without an increase in venous opacification or the presence of venous overlap. No significant differences were found for sensitivity and specificity for the diagnosis of significant stenoses (>70%) and occluded segments. Both agents were well tolerated, and no adverse events were recorded. CONCLUSIONS: The use of a small volume of a high-concentration contrast material yielded higher arterial enhancement from the abdominal aorta down to the femoral arteries with absent or minimal venous overlap and without significant differences in diagnostic ability.
Authors:
Roberto Iezzi; Antonio Raffaele Cotroneo; Antonella Filippone; Daniela Giancristofaro; Maria Luigia Storto
Related Documents :
10424366 - Three-dimensional ct angiographic assessment of vascular diseases using various postpro...
2335596 - Mr imaging of double outlet right ventricle.
17282466 - Extraction of brain vessels from magnetic resonance angiographic images: concise litera...
14599536 - Generalized kohonen's competitive learning algorithms for ophthalmological mr image seg...
21303186 - Lumen irregularity dominates the relationship between mechanical stress condition, fibr...
1442376 - Epilepsy: the role of mr imaging.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Journal of computer assisted tomography     Volume:  32     ISSN:  1532-3145     ISO Abbreviation:  J Comput Assist Tomogr     Publication Date:    2008 Sep-Oct
Date Detail:
Created Date:  2008-10-02     Completed Date:  2008-10-21     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7703942     Medline TA:  J Comput Assist Tomogr     Country:  United States    
Other Details:
Languages:  eng     Pagination:  690-6     Citation Subset:  IM    
Affiliation:
Department of Clinical Science and Bioimaging, Section of Radiology, University G. D'Annunzio, SS. Annunziata Hospital, Via dei Vestini, Chieti, Italy. r.iezzi@rad.unich.it
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Angiography / methods*
Angiography, Digital Subtraction / methods
Aorta, Abdominal / radiography*
Aortography / methods
Arterial Occlusive Diseases / radiography*
Contrast Media / administration & dosage*
Female
Humans
Iopamidol / administration & dosage,  analogs & derivatives*,  diagnostic use
Male
Middle Aged
Prospective Studies
Sensitivity and Specificity
Tomography, X-Ray Computed / methods*
Chemical
Reg. No./Substance:
0/Contrast Media; 62883-00-5/Iopamidol; 78649-41-9/iomeprol

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Cardiovascular Behcet disease: the variable findings of rare complications with CT angiography and c...
Next Document:  Functional computed tomographic quantification of angiogenesis in rabbit VX2 soft-tissue tumor befor...